Specifications
Chapter 5: Installation
To Executive, Standard, Professional, or Associate Display Endpoints
Page 5-216 Mitel
®
5000 Installation Manual – Issue 3.0, October 2008
Figure 5-80. PCDPM Installation on Executive or Standard Display Endpoints
Figure 5-81. Back of 60-Key, 6-Row Digital DSS/BLF Unit
Back of Digital Endpoint
Inside of Baseplate
If the endpoint will be wall-mounted,
open the back of the endpoint and
reroute the Module-to-Keyset Inter-
face cable through this knockout
over to connector J3 on the end-
point control board.
To Chassis
PCDPM
To MDPM
Connector J1
J1
P1
Older PCDPMs, part number 550.3014, require AC transformers when they are connected to DSS/BLF units
only or to PC/output devices only. PCDPMs do not require AC transformers when they are used for OHVA only
or have attached MDPMs. For a diagram of AC transformer requirements, see the Specifications chapter.
Also, some early PCDPM-to-MDPM cables may have the stripe on the wrong edge. If the MDPM does not
respond properly, try reversing the connector on the PCDPM.
J2
To
Handset
J3
To DSS/BLF
Connector J1
Power Connector
Inside of Baseplate
To AC Transformer
J2
J3
J4
Connector
To Endpoint PC Data
Port Module
Connector
To 2nd DSS/BLF
Unit if Installed
J1
Back of Digital DSS/BLF Unit