Specifications

Chapter 5: Installation
Terminating Cables at Digital Endpoint Locations
Page 5-64 Mitel
®
5000 Installation Manual – Issue 3.0, October 2008
Terminating Cables at Digital Endpoint Locations
Terminate the digital endpoint, single line endpoint, and playback device station cables on four-
conductor modular jack [six-conductor line jack unit in Europe] assemblies at the station
locations.
Do not mount the assemblies on the wall at this time; they will be wall-mounted later when the
station instruments are installed. See Figure 5-30 and Figure 5-31 on page 5-64.
Figure 5-30. Modular Jack Assembly Wiring Diagrams (U.S. System)
Figure 5-31. Line Jack Unit Assembly Wiring [European System]
IMPORTANT
If tip and ring are reversed when installing an endpoint, the endpoint will not
function.