Specifications

Chapter 5: Installation
Installing a Four-Port Single Line Module (SLM-4)
Page 5-56 Mitel
®
5000 Installation Manual – Issue 3.0, October 2008
5. Using the IP address of the Inter-Tel 5000 Base Server, open a DB Programming
session to the system through the Session Manager.
6. When DB Studio displays, in the left pane select System and then Communication
Server.
7. Click the Uninstalled bay and click the down arrow.
8. Select Single Line Module - 4.
9. Program the SLM-4 module in the chosen uninstalled bay.
10. Click the SLM-4 folder and configure the ports.
11. Program the individual single line endpoints in DB Programming. For programming
details, refer to the Mitel 5000 Features and Programming Guide, part number 580.8006.
12. Connect and test the endpoints.
NOTE
The programming portion of the SLM-4 installation procedure may be
performed in a local session of DB Programming and then restored to the
system using the Database Restore utility.