Installation guide
Advanced Operational Features
41-001561-00 REV00 – 10.2014 6-48
Creating a Login Key Using the Mitel Web UI
Use the following procedure to create a Login key using the phone’s Web UI:
User Configuration Upload Functionality
Any changes made to a user’s profile while he/she is logged in are saved to the “<user>_local.cfg” file periodically. The time
period between the saves is configurable using the “
user config upload
” and “
user config upload delta
” parameters.
The “user config upload” parameter specifies the time period (in seconds) between the “<user>_local.cfg” saves (while
the user is logged in). To help distribute the file transfers to the configuration server in a more even manner (i.e. so that
the server does not get bombarded by file transfer requests all at the same time) after the initial save, the
“<user>_local.cfg” is saved at a random time period between the values defined in the “user config upload” parameter
and the “user config upload delta” parameter. This latter parameter specifies the upper limit of the extra random time (in
seconds) added to the time defined in the “user config upload” parameter.
Additionally, a “user config upload control” parameter has been implemented that can be used to fine tune when the
“<user>_local.cfg” file should be saved. Administrators can define the parameter as the following:
• 0: Every time the “user config upload” time period expires and at every logout regardless of if the <user>_local.cfg has
changed or not.
• 1: When the “user config upload” time period expires but only if the <user>_local.cfg has changed, and at every logout
regardless of if the <user>_local.cfg has changed or not.
• 2: Only if the <user>_local.cfg has changed. Checked when the “user config upload” time period expires and at logout.
Configuring User Configuration Upload Functionality Using the Configuration Files
Use the following parameters to configure user configuration upload functionality:
Mitel Web UI
1. Click on Operation > Programmable Keys (6863i/6865i) or Softkeys and XML (6867i/6869i)
2. Select from Key 1 through Key 3 (6863i) or Key 8 (6865i) on the programmable keys
or
Select from Key 1 through Key 20 (6867i) or Key 44 (6869i) on the top keys
or
Select from Key 1 through Key 18 (6867i) or Key 24 (6869i) on the bottom keys.
3. In the Type field, select Login to apply to the key.
4. (If available/optional) In the Label field, enter a label to apply to this key (e.g. Login)
5. Click Save Settings.
Configuration Files
For the specific parameters you can set in the configuration files, see Appendix A, the section, “Visitor Desk Phone Settings” on pageA-237.