Specifications
Power
97
• what size UPS would be required to maintain power to the phones in the event of a main
power outage
• if a L2 switch that uses a proprietary PoE (non-802.3af compliant) mechanism has sufficient
power capabilities to power the desired combination of phones.
Notes:
1. The phone power requirements shown in Table 34 do not include the 3300 Power
Dongle power requirements. For example, a 5220 (Dual Mode) phone requires 4.7
watts of power and a 3300 Power Dongle requires 1.4 watts of power. If the 5220
Dual Mode phone is being used in conjunction with a 3300 Power Dongle the power
requirement is 4.7 watts + 1.4 watts for a total power requirement of 6.1 watts.
2. The power values used in Table 34 are based on “maximum worst case” values for
the phones. These values might differ from those shown on a phone data sheet
since the phone data sheets use “typical worst case” values for phone power
consumption.
Table 34: Actual Telephone Power Consumption
Device
Power consumption (W)
(Worst Case Maximum)
5001 IP Phone 2.0
5005 IP Phone 2.6
5010 IP Phone 5.0
5020 IP Phone 5.0
5201 IP Phone 2.0
5205 IP Phone 2.9
5207 IP Phone 3.0
5212 IP Phone 4.7
5215 IP Phone 4.7
5215 IP Phone (Dual Mode) 4.7
5220 IP Phone 4.7
5220 IP Phone (Dual Mode) 4.7
5224 IP Phone 4.7
5230 IP Appliance 5.2
5235 6.2
5140 IP Appliance 6.8
5240 IP Appliance 6.8
5310 IP Conference Unit (for 5235/5330/5330 with backlight/ 5340/5324) (see
Note 2)
5.0
5330 4.7
Page 1 of 3