1. Using an RS-232 cable, connect the printer or PC to
the call logging (SMDR) port on the front of the con-
troller (see Figure 6 (page 74)).
Refer to Serial port pinouts (p. 226) for the pinouts.
The port settings are 9600 baud, 8 bits, No Parity and
1 stop bit (9600 8N1).
Figure 6: Call logging port
2. Launch the system tool.
3. Choose Voice from the Selection menu.
4. Click Management, click Call Logging, and then
click Change.
5. Set the following parameters:
- Set the cost per meter pulse (00 to 999.9). This
functionality is not supported in NA systems
- Set the minimum call duration to be recorded
(00.00.00 to 23:59:59)
- Select the type of calls that you want recorded
- Set the minimum page length (between 10 and
225 lines) for the report. The default is 66 lines.
6. Click Save.
For descriptions of the call logs, refer to Call logging
(SMDR) details (p. 209).