10. Set dipswitch S1 (located closest to the printed circuit
card) to ON to allow diagnostic information to be sent
through the lower DB9 console connector.
11. Connect the lower DB9 male connector on the front
panel of the controller to the female COM port on the
laptop using a CAT5 patch cord.
Do not leave the RS-232 diagnostics cable
disconnected from the computer or laptop COM
port during system bootup (that is, either connect
the cable to the PC or disconnect it from the
diagnostics port).
12. Remove the existing flash card and replace it with the
new flash card. If the flash card does not install easily,
you may have it upside down. See Figure 22 (page
186) for the location of the flash card.
Figure 22: Flash card
13. Launch Hyperterminal and connect to the 3100 ICP
system. See Viewing diagnostics (p. 159).
14. Power up the 3100 ICP system.