Installing the SX-200 ICP MX Controller
The SX-200 ICP system is shipped with the system software and a default
database installed. The optional components (DSP modules, Analog
Option Module, etc.) are field-installed.
1. Install optional controller hardware or peripheral units according to the
instructions on the pages indicated.
Analog Option Board: page 38
DSP Modules: page 40
Dual FIM Module: page 42
Quad CIM Module: page 43
Dual T1/E1 Framer Module: page 44
Upgraded Internal CompactFlash or Hard Drive: page 45
Stratum Clock Module: see page 47
Network Services Unit, page 53
SX-200 Peripheral Cabinets, age 56.
2. Wall mount the units, rack mount them, or place them on a desk or
shelf; see page 31 for instructions.
3. Connect the ground stud on the rear panel of the controller to a hard-
wired ground using 18 AWG (0.75mm 2/) gauge wire. The wire must
have green or yellow insulation. Crimp the wire to the ground source.
4. Connect a PC to the Maintenance port on the controller; see page 84.
5. Connect the trunks and phones. See “Connecting the Phones and
Trunks” on page 67.
6. If you are NOT installing software or optional hardware in the controller,
power up the system.
Note: Premier Business systems use the Premier database which must be
installed before enabling the MOSS Options. For more information, see
“Installing an Alternate Database” on page 201.
Note: The NSU is NOT wall-mountable.