Programming instructions

181
Advanced Installation and Programming
To create Options 60/43 on a Windows 2000 or Windows 2003 DHCP
server:
1. Upgrade the SX-200 ICP to Release 4.0.
2. Upgrade the IP Phone firmware.
3. Start DHCP Manager.
4. In the console tree, click the applicable DHCP server branch.
5. Right-click the server, then click Define Vendor Classes followed by
Add.
6. In the New Class dialog box, type "Mitel Vendor Class" or other name
for the new option.
7. Type "ipphone.mitel.com"in the right side of the text box under ASCII.
8. Enter a null terminator (0x00) at the end of the hex string under Binary.
9. Click OK and then click Close.
10. On the Action menu, select Set Predefined Options.
11. In the Predefined Options and Values dialog box, select the Mitel
Vendor Class from the Option class list. Click Add.
12. In the Option Type dialog box, enter the following:
Field Name... What to enter...
Name Mitel Option
Data Type String
Code 001
13. Click OK.
14. In the Predefined Options and Values dialog box, select 001 Mitel
Option and the Option name and enter the Mitel Information Data
string with the appropriate values for <IP address> and <N>:
id:ipphone.mitel.com;sw_tftp=<IP address>;call_srv=<IP
address>;dscp=<N>;vlan=<N>;l2p=<n>
15. Click OK.
16. Add the Mitel option to the DHCP scopes that require it, modifying the
ID string accordingly.