Programming instructions

180
SX-200 ICP MX Technician’s Handbook
- Type: Hex LONG (32 bit word)
- Code: 132
Click OK.
-Value: enter a numeric value for the VLAN.
10. (Optional) In the Option Type window, set the following:
- Name: Priority
- Type: Hex LONG
- Code: 133.
Click OK.
-Value: enter a value from 1 to 7; Mitel recommends 0x6.
Click OK.
11. Highlight the Scope which contains the IP range for the IP Phones and
select Scope Options.
12. In Action, click Configure Options.
13. In the General window, select option 003 Router and enter the IP
address of the default Gateway and then click Add.
14. Click OK.
Configuring a Windows 2000 DHCP server (Release
4.0 and later)
Note: Options 128-133 used in previous ICP releases are required to
provide backward compatibility with IP sets that have yet to be upgraded
with firmware (version??) that supports options 124/125 or 60/43. After the
upgrade, the old options may be removed to prevent future conflicts with
standard use or with other vendors' use of these options.
Note: The server will automatically convert the numeric value to Hex.
Note: The server will automatically convert the numeric value to Hex.
Note: Neither Windows 2000 nor Windows 2003 support DHCP options
124/125. Options 60/43 must be used instead.