Programming instructions

122
SX-200 ICP MX Technician’s Handbook
IMAT Programming
The IMAT software is used to program hardware and call characteristics
for the NSU and PRI card. IMAT is also used to install software upgrades
and backup the NSU database.
Installing IMAT Software
You can install IMAT on the Maintenance PC or on its own PC (IMAT PC).
To install IMAT on the PC:
1. Close all the applications running on the PC.
2. Insert the SX-200 ICP software CD-ROM in the CD drive.
3. Open the Tools folder, then the Disk 1 folder.
4. Double-click the Setup.exe file. The installation program starts. Follow
the prompts to install IMAT.
Programming IP Settings
Collect the following information:
The Static IP Address that will be programmed on the NSU. Choose
an IP Address that will not conflict with the IP Phone range, which
starts at the default 192.168.1.20 and continues to 192.168.1.250. For
example, you might choose 192.168.1.15 as the static IP address.
The gateway address (if there is a gateway on your network)
The subnet mask (the default setting is 255.255.255.0 which is
represented in hexadecimal as ffffff00)
Note: You must have IMAT software version 7.3 or greater.
Maintenance activities include access to the following maintenance
information:
a list of all software files and versions on the NSU
log messages that contain a history of activities and the status of faults
a database
Note: If using a dial-up connection to the NSU, we strongly suggest that you
use a non-networked computer (a Windows 95/98 networked computer may
have difficulties communicating with Dial-up Networking).