EWP Hangers
Top Mount Hanger Charts
Fastener Schedul
e
5
Uplif
t
2
DF/SP
Ref. No. Ga W H D L TF Type Qty Type LVL PSL LSL SPF DF/SP
160%
HBPH55925 HB5.50/9.25 x 10 5-1/2 9-1/4 3-1/2 -- 3 6 16 16d 10 16d
6185 6185 6185 4910
--
6185
2705
PHXU55925
HWP5.37 H=9.25,
HWPH5.37 H=9.25
x 7 5-1/2 9-1/4 3-1/4 11-1/2 3 4 4 16d 6 10d 5910 5910 5910 4530 -- 5910 1120
HLBH55925 HGLTV5.37 H=9.25 x 7 5-9/16 9-1/4 6 12 3-1/8 3 12 NA16D-RS 6 16d 10045 10045 10045 7680 -- 10045 1580
BPH5595 -- x 12 5-9/16 9-1/2 3 -- 2-5/32 4 6 16d 4 10d 3065 3065 3065 2340 -- 3065 850
HBPH5595 HB5.50/9.5 x 10 5-1/2 9-1/2 3-1/2 -- 3 6 16 16d 10 16d
6185 6185 6185 4910
--
6185
2705
PHM5595 -- x 7/10 5-5/8 9-1/2 2-1/2 7 3 2 -- 16d 2 10d 3265 3265 3265 2480 -- 3265 --
PHXU5595
HWP5.37 H=9.5,
HWPH5.37 H=9.5
x 7 5-1/2 9-1/2 3-1/4 11-1/2 2-1/2 4 4 16d 6 10d 5910 5910 5910 4530 -- 5910 1120
HLBH5595 HGLTV5.37 H=9.5 x 7 5-9/16 9-1/2 6 12 3-1/8 3 12 NA16D-RS 6 16d 10045 10045 10045 7680 -- 10045 1580
HBPH55112 HB5.50/11.25 x 10 5-1/2 11-1/4 3-1/2 -- 3 6 16 16d 10 16d
6185 6185 6185 4910
--
6185
2705
PHXU55112
HWP5.37 H=11.25,
HWPH5.37 H=11.25
x 7 5-1/2 11-1/4 3-1/4 11-1/2 2-1/2 4 4 16d 6 10d 5910 5910 5910 4530 -- 5910 1120
HLBH55112 HGLTV5.37 H=11.25 x 7 5-9/16 11-1/4 6 12 3-1/8 3 12 NA16D-RS 6 16d 10045 10045 10045 7680 -- 10045 1580
5-1/4 x 11-1/2 HLBH55115 -- x 7 5-9/16 11-1/2 6 12 3-1/8 3 12 NA16D-RS 6 16d 10045 10045 10045 7680 -- 10045 1580
BPH55118 -- x 12 5-9/16 11-7/8 3 -- 2-1/32 4 6 16d 6 10d 3050 3050 3050 2340 -- 3050 1275
HBPH55118 HB5.50/11.88 x 10 5-1/2 11-7/8 3-1/2 -- 3 6 16 16d 10 16d
6185 6185 6185 4910
--
6185
2705
PHM55118 -- x 7/10 5-5/8 11-7/8 2-1/2 7 3 2 -- 16d 2 10d 3265 3265 3265 2480 -- 3265 --
PHXU55118
HWP5.37 H=11.875,
HWPH5.37 H=11.875
x 7 5-1/2 11-7/8 3-1/4 11-1/2 2-1/2 4 4 16d 6 10d 5910 5910 5910 4530 -- 5910 1120
HLBH55118 HGLTV5.37 H=11.875 x 7 5-9/16 11-7/8 6 12 3-1/8 3 12 NA16D-RS 6 16d 10045 10045 10045 7680 -- 10045 1580
HBPH5512 -- x 10 5-1/2 12 3-1/2 -- 3 6 16 16d 10 16d
6185 6185 6185 4910
--
6185
2705
PHXU5512 -- x 7 5-1/2 12 3-1/4 11-1/2 2-1/2 4 4 16d 6 10d 5910 5910 5910
4530
-- 5910 1120
HLBH5512 -- x 7 5-9/16 12 6 12 3-1/8 3 12 NA16D-RS 6 16d 10045 10045 10045 7680 -- 10045 1580
BPH5514 -- x 12 5-9/16 14 2-1/2 -- 2-1/32 4 6 16d 6 10d 3050 3050 3050 2340 -- 3050 1275
HBPH5514 HB5.50/14 x 10 5-1/2 14 3-1/2 -- 3 6 16 16d 10 16d
6185 6185 6185 4910
--
6185
2705
PHM5514 -- x 7/10 5-5/8 14 2-1/2 7 3 2 -- 16d 2 10d 3265 3265 3265 2480 -- 3265 --
PHXU5514
HWP5.37 H=14,
HWPH5.37 H=14
x 7 5-1/2 14 3-1/4 11-1/2 2-1/2 4 4 16d 6 10d 5910 5910 5910 4530 -- 5910 1120
HLBH5514 HGLTV5.37 H=14 x 7 5-9/16 14 6 12 3-1/8 3 12 NA16D-RS 6 16d 10045 10045 10045 7680 -- 10045 1580
BPH5516 -- x 12 5-9/16 16 2-1/2 -- 2-1/32 4 6 16d 6 10d 3050 3050 3050 2340 -- 3050 1275
HBPH5516 HB5.50/16 x 10 5-1/2 16 3-1/2 -- 3 6 16 16d 10 16d
6185 6185 6185 4910
--
6185
2705
PHM5516 -- x 7/10 5-5/8 16 2-1/2 7 3 2 -- 16d 2 10d 3265 3265 3265 2480 -- 3265 --
PHXU5516
HWP5.37 H=16,
HWPH5.37 H=16
x 7 5-1/2 16 3-1/4 11-1/2 2-1/2 4 4 16d 6 10d 5910 5910 5910 4530 -- 5910 1120
HLBH5516 HGLTV5.37 H=16 x 7 5-9/16 16 6 12 3-1/8 3 12 NA16D-RS 6 16d 10045 10045 10045 7680 -- 10045 1580
BPH5518 -- x 12 5-9/16 18 2-1/2 -- 2-1/32 4 6 16d 6 10d 3050 3050 3050 2340 -- 3050 1275
HBPH5518 HB5.50/18 x 10 5-1/2 18 3-1/2 -- 3 6 16 16d 10 16d
6185 6185 6185 4910
--
6185
2705
PHM5518 -- x 7/10 5-5/8 18 2-1/2 7 3 2 -- 16d 2 10d 3265 3265 3265 2480 -- 3265 --
PHXU5518 HWPH5.37 H=18 x 7 5-1/2 18 3-1/4 11-1/2 2-1/2 4 4 16d 6 10d 5910 5910 5910
4530
-- 5910 1120
HLBH5518 HGLTV5.37 H=18 x 7 5-9/16 18 6 12 3-1/8 3 12 NA16D-RS 6 16d 10045 10045 10045 7680 -- 10045 1580
1) When I-joist is used as a header, all header nails must be 10d (0.148") x 1-1/2.
2) Uplift loads have been increased 60% for wind or seismic loads; no further increase shall be permitted
3) Some listed loads may be increased for short-term loading. Refer to MiTek code evaluation reports for details.
4) When I-Joists with flanges less than 1-1/2" thick are used as headers, the reduction factor for 1-1/4" flange is 0.69 and 0.84 for 1-3/8" flange.
5) NAILS: 10d nails are 0.148" dia. x 3" long, NA16D-RS nails are 0.148" x 3-1/2" long, 16d nails are 0.162" dia. x 3-1/2" long.
Load tables address hanger/header/fastener limitations only. Joist limitations must be determined for each installation
.
New products or updated product information are designated in blue fon
t
.
5-1/4 x 11-7/8
5-1/4 x 9-1/2
Joist Size
(in)
Top
Qty
Face
Qty
5-1/4 x 14
5-1/4 x 12
MiTek USP
Stock No.
DF
I-Joist
4
Code
Ref.
IBC,
FL,
LA
5-1/4 x 18
5-1/4 x 16
Web
Stiff
Reqd
Allowable Loads Header Type (Lbs.)
1,3
Dimensions (in)
Header Joist Download 100%
5-1/4 x 9-1/4
5-1/4 x 11-1/4
Continued on next page
H
W
L
TF
D