Fire Wall Hangers
Fire Wall Hangers
MiTek
®
Product Catalog
FWHH Heavy-Duty Fire Wall Hangers
The MiTek FWHH Heavy-Duty Fire Wall Hanger is designed
to support beams and purlins at header locations. The higher
capacity of the FWHH is achieved through top ange bearing
along with added face and beam/purlin nailing. As with the FWH
hanger, the advanced design allows you to install the hangers
before the drywall is attached, allowing your project to be
completely framed-up and weather-tight before the drywall
sheathing shows up on site.
Materials: 12 gauge
Finish: Primer
Options: See Specialty Options chart on page 199
Installation:
• Install the FWHH hanger anges tight to the face of the header.
• A minimum 2-ply 2x10 header is required for proper installation.
• The beam/purlin should bear fully on the FWHH seat with a gap
no greater than 1/8" between the end of the supported member
and the hanger.
• Gypsum Wallboard Installation - Use the FWH-T template to slot
cut the gypsum wallboard. See FWH-T Template Sequence. Slide
the gypsum wallboard into position and fasten to the framing
members meeting the minimum requirements specied by code.
FWHH
5-3/4"
FWH-T template
(must be ordered separately)
8"
13"
Typical FWHH
installation
1) Align the FWH-Template slot
with the mark in the gypsum
wallboard and engage the
prongs into edge
of gypsum wallboard
FWH-T Template Installation Sequence
Edge prong
3) Run the gypsum
wallboard cutter
down the template
to cut the slot
2) Rotate the
template and
press down on
the end to engage
the corner prongs
Corner prong
Header
W H D A 100% 115% 125%
3-1/2 x 9-1/2 FWHH3595 9-7/16
3-1/2 x 11-7/8 FWHH35118 11-13/16
3-1/2 x 14 FWHH3514 13-15/16
3-1/2 x 16 FWHH3516 15-15/16
3-1/2 x 18 FWHH3518 17-15/16
3-1/2 x 20 FWHH3520 19-15/16
3-1/2 x 22 FWHH3522 21-15/16
3-1/2 x 24 FWHH3524 23-15/16
1) Uplift Loads have been increased 60% for wind or seismic loads; no further increase shall be permitted.
2) NAILS: 10d x 1-1/2 nails are 0.148" dia. x 1-1/2" long, 10d nails are 0.148" dia. x 3" long.
Header
W H D A 100% 115% 125%
5-1/4 x 9-1/4 FWHH52925 9-1/8
5-1/4 x 9-1/2 FWHH5295 9-7/16
5-1/4 x 11-7/8 FWHH52118 11-13/16
5-1/4 x 14 FWHH5214 13-15/16
5-1/4 x 16 FWHH5216 15-15/16
5-1/4 x 18 FWHH5218 17-15/16
5-1/4 x 20 FWHH5220 19-15/16
5-1/4 x 22 FWHH5222 21-15/16
5-1/4 x 24 FWHH5224 23-15/16
5-1/2 x 9-1/4 FWHH55925 9-1/8
5-1/2 x 9-1/2 FWHH5595 9-7/16
`
5-1/2 x 11-7/8 FWHH55118 11-13/16
5-1/2 x 14 FWHH5514 13-15/16
5-1/2 x 16 FWHH5516 15-15/16
5-1/2 x 18 FWHH5518 17-15/16
5-1/2 x 20 FWHH5520 19-15/16
5-1/2 x 22 FWHH5522 21-15/16
5-1/2 x 24 FWHH5524 23-15/16
7 x 11-7/8 FWHH71118 11-13/16
7 x 14 FWHH7114 13-15/16
7 x 16 FWHH7116 15-15/16
7 x 18 FWHH7118 17-15/16
7 x 20 FWHH7120 19-15/16
7 x 22 FWHH7122 21-15/16
7 x 24 FWHH7124 23-15/16
1) Uplift Loads have been increased 60% for wind or seismic loads; no further increase shall be permitted.
2) NAILS: 10d x 1-1/2 nails are 0.148" dia. x 1-1/2" long, 10d nails are 0.148" dia. x 3" long.
-- 12
Steel
Gauge
Top
Qty
6
DF/SP
Allowable Loads (Lbs.)
Qty
Uplift
160%
2
7715 771520
20
DF/SP
Allowable Loads (Lbs.)
Download
1
Uplift
160%
2
7355
10d x 1-/2
Fastener Schedule
3
Joist
Face
Qty Type
Dimensions (in)
Fastener Schedule
3
Top
Qty
Joist
Type Type
Face
Qty
Joist
Size (in)
MiTek
Stock No.
Ref.
No.
Steel
Gauge
10d
62 3-1/4
4-3/16
20
20
Joist
Size (in)
MiTek
Stock No.
Ref.
No.
10d
Dimensions (in)
Code
Ref.
7685 7715 3445
7715 3445
Download
1
Code
Ref.
--
--
3445
6005 6005 3445
7715 7715
-- 12 7-1/8 2 5-1/16
10d x 1-1/2
Qty
-- 12 5-5/8 2 4-3/16
5-3/8 2
6
Type
-- 12 3-9/16
7715
10d x 1-1/2 60056 20 10d 20
10d x 1-/210d 2020
FWH hangers are tested per ASTM E814 standards. When installed on one
side of a maximum 2 hour fire-rated wall assembly, the penetration of
the MiTek FWH Fire Wall Hanger through the gypsum wallboard will not
reduce the fire resistive rating of the 2 hour fire resistive assembly.
2 Hour Fire-Rating
Continued on next page
A
W
D
H
7-1/2"
2-5/8"