Face Mount Hangers – DF/SP Allowable Loads
Floor
Uplift
1
Joist Size Ref. No. W H D A Qty Type Qty Type 100% 115% 125% 160%
JUS36 LUS36 18 2-9/16 5-1/4 2 1 -- 4 16d 4 16d 1040 1185 1290 1270
10d 1250 1405 1515
16d 1470 1670 1800
HD36 HU36 14 2-9/16 4-3/4 2-1/2 1-1/8 -- 8 16d 6 10d x 1-1/2 1230 1390 1490 760
HD36IF HUC36 14 2-9/16 4-3/4 2-1/2 -- -- 8 16d 6 10d x 1-1/2 1230 1390 1490 760
JUS38 -- 18 2-9/16 6-3/4 2 1 -- 6 16d 4 16d 1325 1510 1645 1270
10d 1250 1405 1515
16d 1470 1670 1800
Min 10 4 1540 1735 1865 760
Max 14 6 2155 2430 2610 1170
Min 10 4 1540 1735 1865 760
Max 14 6 2155 2430 2610 1170
JUS310 LUS310 18 2-9/16 9-1/8 2 1 -- 8 16d 6 16d 1845 2105 2290 2345
10d 2000 2245 2420
16d 2350 2585 2585
Min 10 4 1540 1735 1865 760
Max 14 6 2155 2430 2610 1170
Min 10 4 1540 1735 1865 760
Max 14 6 2155 2430 2610 1170
Min 10 4 1540 1735 1865 760
Max 14 6 2155 2430 2610 1170
Min 10 4 1540 1735 1865 760
Max 14 6 2155 2430 2610 1170
HDQ310IF HUCQ310 14 2-9/16 9 3 1-3/16 -- 8 WS3 4 WS15 3340 3605 3605 1110
10d 2000 2245 2420
16d 2350 2585 2585
Min 10 4 1540 1735 1865 760
Max 14 6 2155 2430 2610 1170
Min 10 4 1540 1735 1865 760
Max 14 6 2155 2430 2610 1170
HDQ310IF HUCQ310 14 2-9/16 9 3 1-3/16 -- 8 WS3 4 WS15 3340 3605 3605 1110
Min 14 6 2155 2430 2610 1170
Max 20 10 3080 3475 3725 1510
Min 14 6 2155 2430 2610 1170
Max 20 10 3080 3475 3725 1510
10d 2250 2525 2725
16d 2645 3000 3240
HDQ310IF HUCQ310 14 2-9/16 9 3 1-3/16 -- 8 WS3 4 WS15 3340 3605 3605 1110
Min 14 6 2155 2430 2610 1170
Max 20 10 3080 3475 3725 1510
Min 14 6 2155 2430 2610 1170
Max 20 10 3080 3475 3725 1510
Min 16 8 2465 2780 2980 1190
Max 24 12 3695 4170 4435 1900
Min 16 8 2465 2780 2980 1190
Max 24 12 3695 4170 4435 1900
1
)
U
p
lift loads have been increased 60% for wind or seismic loads; no further increase shall be
p
ermitted.
2
)
For JUS and HUS han
g
ers: Nails must be driven at a 30° to 45˚ an
g
le throu
g
h the
j
oist or truss into the header to achieve the table loads.
3
)
MiTek's WS15
(
1/4" dia. x 1-1/2" lon
g)
and WS3
(
1/4" dia. x 3" lon
g)
structural wood screws are included with HDQIF han
g
ers.
4
)
NAILS: 10d x 1-1/2 nails are 0.148" dia. x 1-1/2" lon
g
, 10d nails are 0.148" dia. x 3" lon
g
, 16d nails are 0.162" dia. x 3-1/2" lon
g
.
New
p
roducts or u
p
dated
p
roduct information are desi
g
nated in blue font.
755
755
16 6 10d x 1-1/2 1135
11356 10d x 1-1/216
10 4 10d x 1-1/2
16d 10d x 1-1/2
16d 10d x 1-1/2
16d 10d x 1-1/2
10d x 1-1/2
4 10d x 1-1/2
16d
10
10d x 1-1/2
16d 10d x 1-1/2
HD314IF HUC314 14 2-9/16 11-5/16 2-1/2 -- 16d
-- 16d 10d x 1-1/2
HD314 HU314 14 2-9/16 11-5/16 2-1/2 1-1/8
1-1/8
3 x 12
16d 10d x 1-1/2
HD312IF HUC312 14 2-9/16 9-5/16 2-1/2
HD312 HU312 14 2-9/16 9-5/16 2-1/2
3 x 14
SUH314 U314 16 2-9/16 10-9/16 2 1-1/8 --
HD312IF HUC312 14 2-9/16 9-5/16 2-1/2 -- 16d
16d 10d x 1-1/2
10d x 1-1/2
11356 10d x 1-1/218
IBC,
FL,
LA
2-9/16 7-7/16 2-1/2 -- 16d 10d x 1-1/2
-- 16d 10d x 1-1/2
2 1-1/8 --
1-1/8 16d 10d x 1-1/2
1-1/8
2-9/16 8-7/8
HD312 HU312 14 2-9/16 9-5/16 2-1/2 1-1/8
HD310IF HUC310 14
HD310 HU310 14 2-9/16 7-7/16 2-1/2
SUH310 U310 16
HD38 HU38 14 2-9/16 6-3/4 2
HD310IF HUC310 14 2-9/16 7-7/16 2-1/2
3 x 10
SUH310 U310 16 2-9/16 8-7/8 2 1-1/8 --
1-1/8
HD310 HU310 14 2-9/16 7-7/16 2-1/2 1-1/8
HD38IF HUC38 14 2-9/16 6-3/4 2 --
HD38IF HUC38 14 2-9/16 6-11/16 2-1/2 -- 16d 10d x 1-1/2
-- SUH36 U36 16 2-9/16 5-5/16 2
3 x 8
SUH36 U36 16 2-9/16 5-5/16 2
3 x 6
1-1/8
1-1/8
--
HD38 HU38 14 2-9/16 6-11/16 2-1/2
MiTek USP
Stock No.
Steel
Gauge
Min/
Max
Roof
Code
Ref.
Dimensions (in)
Fastener Schedule
3,4
DF/SP
Allowable Loads (Lbs.)
2
Corrosion
Finish
Header Joist
Corrosion Finish
Stainless Steel Gold Coat
HDG Triple Zinc
Corrosion Finish
Stainless Steel Gold Coat HDG Triple Zinc
Corrosion
Finish
Stainless Steel
Gold Coat
HDG
Triple Zinc
A
D
H
W
Continued on next page