Copyright © 2020 MiTek Industries, Inc. All Rights Reser ved
Angles & Straps
Angles & Straps
Corrosion Finish Stainless Steel Gold Coat HDG Triple Zinc
ML angles are multi-purpose angles that install easily with MiTek’s
WS15 structural wood screws. The staggered fastener pattern
allows for back-to-back installations.
Materials: 12 gau ge
Finish: G-185 galvanizing
Codes: IBC, FL, LA
Installation:
• Use all specied fasteners. See Product Notes, page 18.
• MiTek WS15 structural wood screws (1/4" dia. x 1-1/2" long)
are not supplied with ML angles.
ML26-TZ
(ML24-TZ similar)
ML26-TZ
W
W
H
Ref. No. W H Type 100% 115% 125% 160% 100% 115% 125% 160%
ML24-TZ ML24Z 12 2 4 3 3 WS15
655 655 655 655 565 650 655 655
ML26-TZ ML26Z 12 2 6 4 4 WS15 920 1060
1090 1090
755 865
940 1090
1) Allowable loads have been increased 60% for wind and seismic loads; no further increase shall be permitted.
2) MiTek's WS15 structural wood screws are 1/4" dia. x 1-1/2" long and are not included with angles.
3) For exterior applications use MiTek's WS15-EXT structural wood screws with exterior coat finish.
New products or updated product information are designated in
blue font
.
IBC,
FL, LA
MiTek USP
Stock No.
Steel
Gauge
F1 F1
Corrosion
Finish
DF/SP
Allowable Loads (Lbs.)
1
S-P-F
Allowable Loads (Lbs.)
1
Dimensions
(in)
Code
Ref.
Header
Qty
Joist
Qty
Fastener
Schedule
2,3
F1
Typical ML26-TZ
installation
(ML24-TZ similar)
ML Angles
F1
TDL Concrete Angles
These angles secure wood posts to concrete
or wood oors in light-duty applications.
Materials: 12 gauge
Finish: G90 galvanizing
Options: See chart for Corrosion Finish Options
Installation:
• Use all specied fasteners. See Product Notes, page 18.
• The TDL10 can be embedded into concrete. Minimum
embedment depth is 4" to achieve allowable loads.
• Moisture barrier may be required.
TDL10
Typical TDL10
embedded interior
installation
Typical TDL5
interior installation
Corrosion Finish
Stainless Steel Gold Coat HDG Triple Zinc
Anchor Bolts
Ref. No.
W H D Qty Qty Type Qty Dia. (in) Nails Bolts
TDL5 A24 12 2 5-3/16 2-1/4 1 1/2 4 16d 1 1/2
TDL10 A311 12 2 9-3/4 2-1/4 1 1/2 4 16d 1 1/2
1) Allowable loads are based on the use of either nails or bolts; nail and bolt values cannot be combined.
2) The bolt values are based on single shear with a minimum member thickness of 3-1/2".
3) Allowable loads have been increased in accordance with the code; no further increase shall be permitted.
4) Designer must specify anchor bolt type, length, and embedment.
5)
NAILS:
16d nails are 0.162" dia. x 3-1/2" long.
955 1105
Bolts
Strap
--
Corrosion
Finish
Dimensions (in)
Nails
Code
Ref.
Fastener Schedule
4,5
Uplift 160%
Steel
Gauge
DF/SP
Allowable Loads (Lbs.)
1,2,3
Dia.
(in)
MiTek USP
Stock No.
4" min.
embedment
H
D
W