Use and Care Manual

277
Plated Truss
Copyright © 2020 MiTek Industries, Inc. All Rights Reserved
Plated Truss
MiTek
®
Product Catalog
MSSHL/R Severely Skewed Hangers
MiTek’s MSSH217 hanger accommodates a skew range of 60° to 85° (30° maximum off
the girder) without the need for a more expensive custom design hanger. Face nail to
webs or bend the ange strap over the chord. Available in left (L) or right (R) congurations.
Materials: 18 gauge
Finish: G90 galvanizing
Installation:
• Use all specied fasteners. See Product Notes, page 18.
The 3 lower holes on each strap are for top nailing when the strap is bent
over the truss chord. These holes are not for face nailing.
One or both straps may be bent over the bottom chord of the girder with
top or backside nailing.
Note: Select the correct (right or left) hanger so that the strap on the outside
of the angle will pass the end of the truss. When facing the hanger, the strap
in the rear turns in the direction of the skew. The front strap turns to pass
behind the end of the carried member.
Attach the hanger at the end of the truss with a single 10d (0.148" dia.) x
1-12" nail into the side ange or bottom.
Place the truss in position against the girder. Push the outside strap past the end of the
truss to the girder web and face nail through the top 8 holes with 10d (0.148" dia.) x 1-12"
nails for a 1-ply girder, or 10d (0.148" dia. x 3") common nails for multiple-ply girders.
The strap inside the angle can be formed over diagonal webs (if design allows) or
bend over the girder chord. Use two nails into the top and/or back side of the girder.
If the outside strap does not contact a web, bend the strap tightly over the girder
chord. Use two nails into the top and/or back side of the girder.
For uplift resistance, other means of attachment are required. If both the truss
and girder have vertical webs, attach a scab to pack out the girder web nearly
ush with the truss web and use a eld adjustable MP framing angle across
the two. A top chord connection for uplift requires a at LSTA strap tie wrapped
under the girder and over the truss chord.
MSSH217L
Left shown attached
to web and top of chord
MSSH217R
Right shown
attached to webs
Top view right shown
MSSH217R
Right shown
Pocket Nail
8 holes for
face nailing
3 holes for
top nailing
2x6 or 2x8
17-3/16"
1-5/8"
1-3/4"
MSSH217R shown
bent over bottom chord
Additional strapping
for high uplift
Additional strapping
for high uplift
Back view shown
Floor Floor
Qty Type Qty Type Qty Type 100% 115% 125% 100% 115% 125%
face-max -- -- 16 10d 1 Ply 1755 1770 1770 1140 1155 1165
top-min 4 10d 6 10d 1 Ply 1735 1735 1735 1140 1155 1165
1) No uplift value with this hanger. Use other hardware or nailing higher on supported member to counteract uplift.
2) One or both straps may be bent over bottom chord of girder with top or backside nailing.
3) Maintain minimum 3/4" edge distance when installing nails.
4) The supported member shall be supported by blocking or other means to prevent rotation.
5)
NAILS:
10d x 1-1/2 nails are 0.148" dia. x 1-1/2" long, 10d nails are 0.148" dia. x 3" long.
Note: The 3 lower holes on each strap are for top nailing when strap is bent. These holes are not for face nailing.
MSSH217L/R --
Top
1 10d x 1-1/2
Ref.
No.
MiTek USP
Stock No.
Steel
Gauge
Mounting
Condition
Supported
Member
4
Supporting Member
Face/
Backside
18
Fastener Schedule
2,3,5
--
DF/SP
Allowable
Loads (Lbs.)
1
S-P-F
Allowable
Loads (Lbs.)
1
Roof
Girder
Truss
Roof
Code
Ref.
MP Framing
Angle pg. 109
Back side with
straps bent over
LSTA Strap
Tie pg. 122
Bend over
Bend over
Girder
Truss