Use and Care Manual

Caps & Bases
101
Copyright © 2020 MiTek Industries, Inc. All Rights Reserved
Caps & Bases
MiTek
®
Product Catalog
KCCQ / KECCQ Column Caps
Bearing
1
Uplift
2,8
Ref. No.
W1 W2 H L Qty Type Qty Type 100% 160%
KCCQ71-4 CCQ7.1-4SDS2.5 3 7-1/4 3-5/8 6-1/2 11 16 WS3 14 WS3 48125 7065
KCCQ71-6 CCQ7.1-6SDS2.5 3 7-1/4 5-1/2 6-1/2 11 16 WS3 14 WS3 48125 7065
KCCQ71-71 CCQ7.1-7.1SDS2.5 3 7-1/4 7-1/4 6-1/2 11 16 WS3 14 WS3 48125 7065
KCCQ71-8 CCQ7.1-8SDS2.5 3 7-1/4 7-1/2 6-1/2 11 16 WS3 14 WS3 48125 7065
KCCQ84 -- 7 7-1/2 3-5/8 6-1/2 11 16 WS3 14 WS3 51565 7065
KCCQ86 CCQ86SDS2.5 7 7-1/2 5-1/2 6-1/2 11 16 WS3 14 WS3 51565 7065
KCCQ88 CCQ88SDS2.5 7 7-1/2 7-1/2 6-1/2 11 16 WS3 14 WS3 51565 7065
KCCQ94 -- 7 8-7/8 3-5/8 6-1/2 11 16 WS3 14 WS3 60155 7065
KCCQ96 CCQ96SDS2.5 7 8-7/8 5-1/2 6-1/2 11 16 WS3 14 WS3 60155 7065
KCCQ98 CCQ98SDS2.5 7 8-7/8 7-1/2 6-1/2 11 16 WS3 14 WS3 60155 7065
KCCQ106 CCQ106SDS2.5 7 9-1/2 5-1/2 6-1/2 11 16 WS3 14 WS3 65315 7065
KECCQ325-4 ECCQ3-4SDS2.5 7 3-1/4 3-5/8 6-1/2 7-1/2 16 WS3 14 WS3 14650 6860
KECCQ325-6 ECCQ3-6SDS2.5 7 3-1/4 5-1/2 6-1/2 7-1/2 16 WS3 14 WS3 14650 6860
KECCQ44 ECCQ44SDS2.5 7 3-5/8 3-5/8 6-1/2 8-1/2 16 WS3 14 WS3 16965 6860
KECCQ45 -- 7 3-5/8 5-3/8 6-1/2 7-1/2 16 WS3 14 WS3 16405 6860
KECCQ46 ECCQ46SDS2.5 7 3-5/8 5-1/2 6-1/2 8-1/2 16 WS3 14 WS3 18595 6860
KECCQ47 -- 7 3-5/8 7-1/8 6-1/2 9-1/2 16 WS3 14 WS3 20780 6860
KECCQ47X -- 7 3-5/8 7-1/8 6-1/2 9-1/2 16 WS3 14 WS3 20780 6860
KECCQ48 ECCQ48SDS2.5 7 3-5/8 7-1/2 6-1/2 8-1/2 16 WS3 14 WS3 18595 6860
KECCQ525-4 ECCQ5-4SDS2.5 3 5-1/4 3-5/8 8 9-1/2 16 WS3 14 WS3 22330 6860
KECCQ525-6 ECCQ5-6SDS2.5 3 5-1/4 5-1/2 8 9-1/2 16 WS3 14 WS3 27300 6860
KECCQ525-8 ECCQ5-8SDS2.5 3 5-1/4 7-1/2 8 9-1/2 16 WS3 14 WS3 30430 6860
KECCQ57 -- 7 5-3/8 7-1/8 6-1/2 9-1/2 16 WS3 14 WS3 31170 6860
KECCQ64 ECCQ64SDS2.5 7 5-1/2 3-5/8 6-1/2 8-1/2 16 WS3 14 WS3 23535 6860
KECCQ66 ECCQ66SDS2.5 7 5-1/2 5-1/2 6-1/2 8-1/2 16 WS3 14 WS3 28910 6860
KECCQ67X ECCQ6-7.13SDS2.5 7 5-1/2 7-1/8 6-1/2 8-1/2 16 WS3 14 WS3 29220 6860
KECCQ68 ECCQ68SDS2.5 7 5-1/2 7-1/2 6-1/2 8-1/2 16 WS3 14 WS3 29220 6860
KECCQ74 ECCQ74SDS2.5 3 6-7/8 3-5/8 6-1/2 8-1/2 16 WS3 14 WS3 27465 6860
KECCQ76 ECCQ76SDS2.5 3 6-7/8 5-1/2 6-1/2 8-1/2 16 WS3 14 WS3 35860 6860
KECCQ77 ECCQ77SDS2.5 3 6-7/8 6-7/8 6-1/2 8-1/2 16 WS3 14 WS3 35860 6860
KECCQ78 ECCQ78SDS2.5 3 6-7/8 7-1/2 6-1/2 8-1/2 16 WS3 14 WS3 35860 6860
KECCQ71-4 ECCQ7.1-4SDS2.5 3 7-1/4 3-5/8 6-1/2 8-1/2 16 WS3 14 WS3 28240 6860
KECCQ71-6 ECCQ7.1-6SDS2.5 3 7-1/4 5-1/2 6-1/2 8-1/2 16 WS3 14 WS3 35285 6860
KECCQ71-71 ECCQ7.1-7.1SDS2.5 3 7-1/4 7-1/4 6-1/2 8-1/2 16 WS3 14 WS3 37190 6860
KECCQ71-8 ECCQ7.1-8SDS2.5 3 7-1/4 7-1/2 6-1/2 8-1/2 16 WS3 14 WS3 37190 6860
KECCQ84 -- 7 7-1/2 3-5/8 6-1/2 8-1/2 16 WS3 14 WS3 29785 6860
KECCQ86 ECCQ86SDS2.5 7 7-1/2 5-1/2 6-1/2 8-1/2 16 WS3 14 WS3 37390 6860
KECCQ88 ECCQ88SDS2.5 7 7-1/2 7-1/2 6-1/2 8-1/2 16 WS3 14 WS3 39845 6860
KECCQ94 -- 7 8-7/8 3-5/8 6-1/2 8-1/2 16 WS3 14 WS3 33595 6860
KECCQ96 ECCQ96SDS2.5 7 8-7/8 5-1/2 6-1/2 8-1/2 16 WS3 14 WS3 42630 6860
KECCQ98 ECCQ98SDS2.5 7 8-7/8 7-1/2 6-1/2 8-1/2 16 WS3 14 WS3 46485 6860
KECCQ106 ECCQ106SDS2.5 7 9-1/2 5-1/2 6-1/2 8-1/2 16 WS3 14 WS3 45760
6860
1
)
Bearin
g
loads are based on 625
p
si
p
er
p
endicular to
g
rain loadin
g
; no further increase for duration of load is
p
ermitted.
2
)
U
p
lift loads have been increased 60% for wind or seismic loads; no further increase shall be
p
ermitted.
3
)
Allowable loads are based on lumber with a s
p
ecific
g
ravit
y
of 0.50 and a moisture content of 19% or less.
4
)
WS3 structural wood screws are 1/4" dia. x 3" lon
g
and are included with KCCQ and KECCQ column ca
p
s.
5
)
Beams shall be desi
g
ned to su
pp
ort the re
q
uired loads. Beam shear ma
y
limit loads to less than listed loads for device.
6
)
The desi
g
ner shall check
p
ost for re
q
uired loads.
7
)
S
p
liced conditions must be detailed b
y
the s
p
ecifier to transfer tension loads between s
p
liced members b
y
means other than the column ca
p
.
8
)
U
p
lift loads do no a
pp
l
y
to s
p
lice conditions.
New
p
roducts or u
p
dated
p
roduct information are desi
g
nated in blue font.
IBC,
FL,
LA
End Column Caps
MiTek USP
Stock No.
Steel
Gauge
Code
Ref.
Center Column Caps
IBC,
FL,
LA
Column
or Post
Fastener Schedule
4
Beam
Corrosion
Finish
DF/SP
Allowable Loads
(Lbs.)
3
Dimensions (in)
Continued on next page
Corrosion Finish
Stainless Steel Gold Coat
HDG Triple Zinc
Corrosion Finish Stainless Steel Gold Coat HDG Triple Zinc
Corrosion
Finish
Stainless Steel
Gold Coat
HDG
Triple Zinc