Technical Specifications

SSppeecciiaallttyy OOppttiioonnss
1-800-328-5934 • www.USPconnectors.com
208
© Copyright 2007 USP Structural Connectors
®
Slope
angle
Specify
angle
Joist skew
right shown
Specify angle
Specify
angle
Open Top Flange Hanger Specialty Details
Skew angle
Slope angle
Specify angle
high side flush
low side flush
center flush
Typical BPH hanger
skewed right,
sloped down, top
flange sloped
Specify angle
Typical BPH hanger
skewed, left shown
Type A
(bevel cut required)
Specify angle
Typical PH hanger
skewed, left shown
Type B
Typical PH hanger
skewed, left shown
Type A
(bevel cut required)
Plumb
height
Specify
angle
Joist
height
Typical BPH hanger
sloped seat,
down shown
Typical BPH hanger
sloped down,
skewed right, low
side flush shown
Typical LBH hanger
sloped top flange
right shown
Typical BPH hanger
skewed, right shown
Type B
See Specialty Options Chart for each hanger series for load
reductions and hanger maximum range of skew, slope, etc.
Skewed Hanger:
Joist nails may be located on obtuse side to ensure proper
nailing.
Specify skew angle, type (A or B), and direction when ordering.
Sloped Seat Hanger:
Additional nail holes may be added to joist flanges.
Specify slope angle, direction, and joist height when ordering.
Sloped/Skewed Hanger:
See nailing notes for both skewed and sloped hangers.
Specify skew and slope angles as well as skew/slope
directions, and skew type (A
or B) when ordering.
Specify if hanger is to be high side flush, low side flush, or
center flush.
See Specialty Options Chart for each hanger series for load
reductions and hanger maximum range of skew, slope, etc.
S
kewed Hanger:
Joist nails may be located on obtuse side to ensure
p
roper nailing.
Specify skew angle, type (A or B), and direction
when ordering.
S
loped Seat Hanger:
Additional nail holes may be added to joist flanges.
Specify slope angle, direction, and joist height when
ordering.
Sloped/Skewed Hanger:
See nailing notes for both skewed and sloped hangers.
Specify skew and slope angles as well as skew/slope
directions, and skew type (A or B) when ordering.
Similar to face mount skewed/sloped hanger, refer to
illustration on page 207: Typical HD hanger sloped
down, skewed left shown.
Specify if hanger is to be high side flush, low side flush,
or center flush.
Sloped/Skewed/Sloped Top Flange Hanger:
See nailing notes for both skewed and sloped hangers.
Specify skew, slope, and top flange slope angles as
well as skew/slope and top flange slope directions
when ordering.
Skewed/sloped/top flange sloped hangers can be
made galvanized or painted.
continued on next page
Solid Top Flange Hanger Specialty Details