Service manual
Copystar Focus Volume 8 Number 1
Page 12
Helpful Hints
From The Copystar Diagnostic Center
Sure-Test SD-1D Digital Circuit Analyzer
The Diagnostic Center has been receiving a number of calls that have been traced to power problems at the
Customer’s location. Acceptable power requirements are crucial when setting up Digital Copier/Laser Printers.
Potential Power Problems can be quickly identified using the Sure-Test SD-1D Digital Circuit Analyzer. The Chart
below outlines the acceptable range of the test results when using the Sure-Test SD-1D Digital Circuit Analyzer.
The Power Supply at the Customer’s location should be checked before and after the installation of all Copystar
Equipment.
Test # Test Description Acceptable Range
1 Line Voltage 108-132V AC
2 % voltage drop 15A < 5%
3 % voltage drop 20A < 5%
4 Ground/neutral voltage < 1.0V AC
5 % load on line < 1%
6 Ground Impedance < 0.25 ohms
The Sure Test SD-1D Digital Analyzer can be purchased from EPS, 517 North Industrial Drive, Zebulon, NC 27597. Phone 1-
800-645-9721 or www.realpowerprotection.com
Ci 7600
Change to the Part Number for the Front Cover
An incorrect part number (50307280) was listed in the Ci 7600 Parts List for the Front Cover. The correct Part
Number should read (5BL07300).
Parts Information
Old P/N New P/N Description Qty.
Old/New
Interchangeability Price
50307280 5BL07300 Front Cover 1/1 Y/Y $150.18
RC-3010/2310
Shipping Change for the Transfer Roller
The Transfer Roller Ass’y will no longer be taped to
the Inner Tray during Shipping. The Transfer Roller
Ass’y will now be installed in the machine from the
Serial Numbers listed: RC-2310/37009955,
RC-3010/37008999.
Note: It is not necessary to remove the Transfer
Roller during Developer setup.
Transfer
Roller