Input/Customer Interface Connections
Input Power Connector (J1) - See Fig. 8
Input AC power is applied to connector J1 using 3W3 Power Con-
nector
Use ITT/Cannon mating receptacle P/N DAM3W3SA197 with pins
P/N DM53744-6
A fault clearing device, such as a fuse or circuit breaker, with a
maximum 15 A rating should be used at the power supply input
Customer Interface Connector (J2) - See Fig. 9
J2-1 to 3 are Enable/Disable for output card locations 1-3,
respectively
J2-4 is Signal Ground.
J2-5 is +5 VDC
J2-6 is AC Power OK
J2-7 is General Shutdown
Use ITT/Cannon mating plug P/N DE9PK87 with Amp cover
shell P/N 205729-1
Attach terminals to 22-24 AWG stranded wire
Figure 8. Input Connector
Figure 9. Customer Interface Connector
J1 Pin Out
A1 Line
A2 Line 2/Neutral
A3 Ground



J2 Pin Out
1 E/D-1
2 E/D-2
3 E/D-3
4 Signal Ground
5 +5V Vcc @ 100 mA
6 AC Power OK
7 GSD (General Shutdown)
8 Spare