Operator`s manual

Badger II Power Supply Operator’s Manual
Rev. 05/11/2012 Mission Power Solutions (760) 631-6846 sales@mpwrs.com Pg. 15
Environmental
MIL-STD
810E
Storage Temperature
Industrial Grade
55C to 125C
Military Grade
65C to 125C
Commercial Grade
40C to +125C
Operating Temperature
Industrial Grade, Full Power
40C to 45C
Industrial Grade, Half Power
40C to 65C
Military Grade, Full Power
55C to 45C
Military Grade, Half Power
55C to 65C
Commercial Grade, Full Power
20C to +45C
Commercial Grade, Half Power
20C to +65C
Product Weight
7.0 lbs.
Storage Temperature
C-Grade
40C to 125C
T-Grade
40C to 125C
H-Grade
55C to 125C
M-Grade
65C to +125C
Max Operating Temperature Range
(See temperature derating chart on next page)
C-Grade
20C to +65C
T-Grade
40C to 65C
H-Grade
40C to 65C
M-Grade
55C to 65C
Humidity
95%, non-condensing (conformal coating available)
Altitude
Operational Full power to 20,000 ft (6,000 m)
Non-operational 40,000 ft (12,000 m)
Shock
MIL-STD-810E, Method 516.4, Fig 516.4-4
Functional 40 g, 11 ms
Crash Safety 75 g, 6 ms
Vibration
MIL-STD-810E, Method 514.4, Category 10, Figs 514.4-16 & -17
Random 20-1000 Hz @ 0.04 g
2
/Hz; 2 kHz @ -6 dB/octave; 7.7 grms
Sine 5-14 Hz @ 0.2"; 14-33 Hz @ 2 g;
33-52 Hz @ 0.036"; 52-500 Hz @ 5 g
Badger II Output Power vs. Input Voltage
Do not exceed maximum power rating vs. temperature. See table on next page.