Operator`s manual

Badger II Power Supply Operator’s Manual
Rev. 05/11/2012 Mission Power Solutions (760) 631-6846 sales@mpwrs.com Pg. 14
(Typical at 25C, nominal line and 75% load, unless otherwise specified)
Number of Outputs 1-12
Efficiency 80%, typical (depends on output V & I)
Safety Approvals None
Maximum Output Power @ 35°C 800 W @ 110 VAC/VDC
1,800 W @ 220 VAC/VDC
Product Weight 10.0 lbs.
Dimensions 2.55"H (64,8mm) x 7.0"W (177,8mm) x 13.75"L (349,3mm)
Warranty 1 Year Limited
General
Input
Input 85-254 VAC, 47-500 Hz
85-380 VDC
Line Regulation 0.2% from 10% load to full load
Inrush Current 30 A rms max @ 110 VAC
60 A rms max @ 220 VAC
Ride-Through Time 20 ms at 1,200 W load
EMIConducted Emissions FCC Class B, EN 55022 Class B
MIL-STD-461E CE101, CE102
EMIConducted Susceptibility MIL-STD-461E CS101, CS114, CS115, CS116
Power Factor 0.99 (115 VAC, 800 W load)
0.95 (230 VAC, 1,200 W load)
Dielectric Withstand Primary to Chassis GND = 2,121 VDC
Primary to Secondary = 4,242 VDC
Secondary to Chassis GND = 500 VDC
Output
Parameter MIN. TYP. MAX. UNITS NOTES
Setpoint Accuracy
0.5 1
% of V
NOM
Load/line Regulation
0.02 0.2
% of V
NOM
0% to 100%
Temperature Regulation
0.002 0.005
%C 20 to 65C
Long Term Drift
0.02
%1 k hours
Output Ripple pp:
≤5 V 100 mV 20 MHz bandwidth
≥12 V 1 % 20 MHz bandwidth
Trim
10 110 % of V
NOM
Total Remote Sense Compensation
0.5 Volts 0.25 V max each leg
OVP Set Point
112 135 % of V
NOM
Recycle power
Current Limit
102 135 % of Imax Automatic restart
Over-Temperature Protection
70
C
Varies with power level
Specifications