Installation Sheet

Page
Cered 01/04/2017
QCI-5305 Rev 0
SUPPORT BAR
In some applicaons, the unit requires installing a support bar to make the enclosure
safe. The support bar aaches to the panel and screws into the wall. Note: The
support bar as packaged is not cut to length.
Support bars are included with every enclosure they are required on. To install, nd
the Panel Mount (NN) and loosen the Panel Clamp Screw (MM) and place the panel
mount on the glass panel approximately 6” away from the edge of glass as shown.
Next, measure from the center of the Panel Mount (NN) to the wall. Note the
measurement and mark a hole at that distance on the return wall. Drill a 3/16”
diameter hole approximately 1-1/2” deep on your mark.
Insert a wall plug and cut o the head with a razor blade. Fasten the Bushing (QQ) to
the wall using the Bushing Screw (RR). Loosen the Bushing Clamp Screw (OO), place
the Wall Mount (II) onto the bushing, and make it ush against the wall.
Measure approximately the distance between the Wall Mount (II) and Panel Mount
(NN) where the Support Bar (JJ) will sit. Cut the support bar about 1/2” longer than
your measurement.
To mount the bar, the Panel Mount (NN) needs to be removed and both Bar Screws
(KK & PP) need to be loosened. Remove the Panel Mount (NN) and place one end of
the support bar into the Wall Mount (II). Slide the Panel Mount (NN) onto the
Support Bar (JJ) and posion the angle adjuster so it ts onto the panel. It is ok if the
Panel Mount (NN) is not exactly 6” from the edge. Finally, ghten all screws.
10
Measure
6”
Repeat Measure
Drill 3/16” Hole