Installation Sheet

QCI-5307 Rev 0 Page 9 Cered 01/05/17
7 Refer to the sizing chart below to properly orient
the Glass Panel according to the unit range. Meas-
urement is from edge of glass to the header bar as-
sembly hole*
Carefully set the fixed panel into the u-channel, rest-
ing it on setting blocks. Slide the panel into the wall
mounted u-channel.
Exposed edges must be level and plumb before
moving to next step. Check and adjust shimming
as required.
8 Unscrew the Panel Mount Caps from the Header Assembly.
Slightly loosen the Mount Screw inside to allow for adjustment of the mount brackets to fit the
mounting holes in the fixed panel.
Position the Header Assembly to align the Panel Mounts in the proper mounting holes on the Fixed
Panel. Tighten the Mount Screws.
*Panel Glass Sizing Chart
Unit Range Wall Side Door Side
44 1/2" - 45 3/4" 5 1/2" 6 7/8"
45 3/4" - 47 1/2" 6 7/8" 5 1/2"
56 1/2" - 57 5/8" 5 1/2" 6 7/8"
57 5/8" - 59 1/2" 6 7/8" 5 1/2"
Door Side
Outside of Shower
Wall Side
Mount Screw
Panel Mount
Panel Mount Cap