BLE 3000 Module User's Guide
General
2.6 Module Management
The Module Management Mode is configurable using DMCUser software.
When a dosimeter is configured in "All" mode and has been
equipped with a module, the "Detach Module" command
resets the fault message "Mod def" and return to operate
without any module.
Note that the behavior is the same for battery removal.
Note: This command resets the secondary dose of the dosimeter.
Note: if the dosimeter is configured in "Neutron required" or "Hp(0,07) required" mode, this command resets the secondary
dose but it does not modify dosimeter operation.
None: any module connection is ignored by the dosimeter.
All: DMC 3000 accepts any type of modules. When a module is connected, the dosimeter automatically
changes its display configuration and displays the Hp(10) neutron or Hp(0,07) shallow dose depending on
the type of module.
Hp(0,07) required / Telemetry required / Neutron required / NTx required / eTx required / Bluetooth
required: DMC 3000 needs the required module otherwise a default message "WRG MOd" is displayed or
"Mod def" if no module is connected.