Manual

www.mirion.com
Format A4
Health Physics
Division
Sincenorms,specicationsanddesignsaresubjecttooccasionalchange,pleaseaskforconrmationoftheinformationgiveninthispublication.
©Copyright2012,Allrightsreserved.Fortrademarkandregisteredtrademarkinformation.ThecopyrightinthisworkistheexclusivepropertyofMirionTechnologies
(RADOS)GmbHandisprotectedunderthelawsofGermanyandothercountriesworldwide.
MirionTechnologies(MGPI)Inc
5000HighlandsParkway
Suite150
SmyrnaGeorgia30082
USA
T +1.770.432.2744
F +1.770.432.9179
MirionTechnologies(MGPI)SA
Lieu-DitCalès
Routed‘Eyguières
F-13113Lamanon
France
T +33(0)490595959
F +33(0)490595518
MirionTechnologies
(RADOS)Oy
P.O.Box506
FIN-20101Turku
Finland
T +35824684600
F +35824684601
MirionTechnologies
(RADOS)GmbH
Ruhrstrasse49
D-22761Hamburg
Germany
T +4940851930
F +494085193256
MirionTechnologiesShanghaiBranch
Room801,78Jiangchang
SanLu,ZhabeiDistrict
Shanghai200436
China
T +862161806920
F +862161806924
TECHNICAL SPECIFICATIONS
Overview of Features
ImprovedGeometry
• TheRADOSCheckPoint:Body™familymemberTwoStep™-GasIIisdesignedwithdetectorsshaped
aroundthebodyforpersonnelcontaminationandinternalcontaminationscreeningatcheckpoints.
Radioactiveornuclearcontaminationdetectionisincreasedsystematicallybydecreasingdetector
deadzonesinthiscontaminationmonitor.
Newgasowdetectordesign
• Muchimprovedoveralldetectionprobabilityduetohomogeneousdetectionresponseover
thelengthofthemonitormadepossiblebysignicantlyreduceddeadzones.
• Fastandeasyfoilchange
• Automaticre-addressingofdetectorsafterreplacement
• Quickushingofdetectorswithcountinggas
Stateofthearthardwaredesign
• Newone-piecedatacollectorelectronicsconnectsdetectorsandstandardindustrialPC
• Touchscreenuserinterface
• LEDlightinginsidethemonitor
• choiceoftwomonitordepths(800mmor1000mm)
Designedforperformanceinnuclearenvironments
• Discriminatesalpha,betaandoptionalgammaradiationwithimproveddetectionlimits
• Radoncompensation
• Stainlesssteelhousing,easilydecontaminated,easymaintenance
Customer Benefits
Highthroughput
• Softwareonthebasisofthereal-timeQNXoperatingsystemproveninmanygenerations
ofRADOSmonitors.
• Option:P
2
acceleratorreducesmeasurementtimeupto30%
Lowcostofoperationandmaintenance
• LesselectronicpartsthantheRTM860TS
• Rigorousstandardizationofpartsdecreasesneedtoholdalargevarietyofspares(e.g.detectorsize)
• SoftwaremaintenancetoolsprovenovertheCheckPoint:Body™familyofmonitors
• Automaticaddresssettingofthedetector
• Changingfoilonthedetectormadeeasybysimpledetectordesign;allowsfastin-the-eldrepairby
customer’stechnician-resultinginlowermaintenancecosts
• Quickerushingofthedetectorswithgasduetodesignoftubesanddetectorgasinletnozzles
Abilitytonetwork
• OptionallinkupwithCeMoSys™serverforcentralisedmonitoring
References
TheTwoStep™-GasIImonitoroftheCheckPoint:Body™familyistheidealmonitortocontrolthe
exitpointsfromcontrolledareasinnuclearfacilitieswith
• potentialalphaandbetacontamination(gammaasoption)
• potentialRadonbackground
• highthroughputrequirements
7NUC_TSG_Y019-009E_1_FL
RADOSTwoStep™-GasII
WholeBodyContaminationMonitor
CheckPoint:Body™family