Manual
5000 Highlands Parkway
Suite 150
Smyrna Georgia 30082
USA
T +1.770.432.2744
F +1.770.432.9179
BP 1
F-13113 Lamanon
France
T +33 (0) 4 90 59 59 59
F +33 (0) 4 90 59 55 18
P.O. Box 506
FI-20101 Turku
Finland
T +358 2 4684 600
F +358 2 4684 601
Ruhrstrasse 49
D-22761 Hamburg
Germany
T +49 40 85193 0
F +49 40 85193 256
132682B
TeleView 2000
Remote Monitoring Software
www.mirion-hp.com
TECHNICAL REQUIREMENTS:
Features
TeleView 2000 will automatically associate worker information from an ODBC Compliant•
Access Control system or a local database with a device for display.•
All Clients operate with the same master conguration.•
True Client Server Operation•
Connection less data transmission•
TCP/IP based repeaters for segmented networks•
Unlimited number of TeleView Clients•
Clients allow full customization of containers including column width, column order, column sorting, column visibility, column locking, column •
names, container size and location with default column presets and individual container overrides for each Client.
User-dened containers ltered by RWP numbers•
Ability to hide or display any information placed in containers•
Ability to display trend graphs for each entry•
Color-coded status for alarms, warnings, lost contacts, and network and instrument connections•
Distributed application: a TeleView Net client station can monitor data from a remote TeleCast server as long as the client can communicate •
with the server through UDP
Air, area, and personnel monitoring with the same program for a global and eective solution•
Automatic connection to the AC database when the program is started•
Minimal user requirements, providing more time to monitor people•
Standard Microsoft Windows interface for all functions•
Secure read-only access to the AC database•
Easy remote conguration of TeleCast through TeleView Net Clients•
Global conguration of alarms and warning set-points. All Clients see the same alarms.•
Ability to save and recall custom screen congurations •
Hardware Requirements
Server/Client Combination:
2.0 GHz P4 CPU•
1024 x 768 or higher resolution•
512 Megabytes RAM•
10 Gigabytes available hard drive space with 4 Gigabytes contiguous•
Dual displays (PCI video cards that support multiple displays under Microsoft Windows. Add 300 Mhz, 2 Gig Contiguous Hard Drive space, and •
128Meg memory for each additional video display)
minimum 17” monitor(s)•
Requirements vary for stand-alone congurations – contact MGPI
Communications Specications
Network: TCP/IP Protocol•
Inputs thru Serial Link: WRM2 Base, WRM-Plus Base, DDC-16/Plus, AM-16•
Inputs Thru Network Card: WRM2 Base, WRM-Plus Base, DDC-16/Plus, AM-16•
Software Platform Requirements
Operating System: Microsoft Windows 2000/XP•
ODBC Drivers for Access Control Connectivity•