SPN DETECTORS
Neutron Flux Instrumentation
www.mirion.com
145028EN-B
348 244 EN-C
PREFERRED TYPES OF THE IST-PROGRAM
Notice: 1 nv = 1/cms
COMMON DATA
● Operating temperature: 400°C max. (752°F)
● Diameter of detector and cable: 1.6 mm
● Connector: BNC-Plug
● Material of detector and cable sheath: stainless steel
● Insulation: Al2O3 or MgO
● Manufacturer: Mirion Technologies (IST) Corporation,
Horseheads, NY/USA
Type Emitter
Material
Neutron
Sensitivity
(A/nv)
Gamma
Background
Measuring
Range
(nv)
Response
Time
(s)
Detector
Length L1
(mm)
Total
Length L2
(mm)
WL-23215
WL-23226
WL-23283
Rhodium
Vanadium
Cobalt
1.0e-20
1.1e-20
1.4e-21
2%
2%
5%
1e9 ... 1e15
1e9 ... 1e15
1e10...1e15
60
300
1e-10
76
1.321
864
8 543
9 144
4 877