User Manual

Health Physics
Division
Since norms, specications and designs are subject to occasional change, please ask for conrmation of the information given in this publication.
Mirion Technologies (MGPI) Inc
5000 Highlands Parkway
Suite 150
Smyrna Georgia 30082
USA
T +1.770.432.2744
F +1.770.432.9179
Mirion Technologies (MGPI) SA
Lieu-Dit Calès,
Route d’Eyguières
F-13113 Lamanon
France
T +33 (0) 4 90 59 59 59
F +33 (0) 4 90 59 55 18
Mirion Technologies (RADOS) Oy
P.O. Box 506
FIN-20101 Turku
Finland
T +358 2 468 4600
F +358 2 468 4601
Mirion Technologies (RADOS) GmbH
Ruhrstrasse 49
DE-22761 Hamburg
Germany
T +49 (0) 40 851 93-0
F +49 (0)40 851 93 256
Mirion Technologies Shanghai Branch
Room 801, 78 Jiangchang
San Lu, Zhabei District
Shanghai 200436
China
T +86 21 6180 6920
F +86 21 6180 6924
SPIR-IDENT PEDESTRIAN GN
Detection and Identication - Risks Prevention
www.mirion.com
145396EN-E
DESCRIPTION
1 to 4 detection pillars including each a 2 or 4 liter
NaI(Tl) gamma detector and 1 or 2 moderated He3 or
BF3 neutron detectors
3 sided lead shielding
Each gamma detector is associated with a fast digital
spectrometer
Standard or Panel PC with SPIR-IDENT Server software,
Portal and Expert mode interface
Includes SIA identication algorithm designed for
challenging Homeland Security issues
Remote cameras control option
With or without occupancy signal
FUNCTIONS
0,5 second continuous elementary spectra acquisition
and stabilization (sourceless)
Count rate and dose rate calculation, alert criteria
monitoring
Self-triggered spectra accumulation capability if alert
Real-time identication per channel and group of
channels
Automated results and pictures capture every half
second during alarms
Sliding spectra analysis between occupancies to
monitor background
Manually triggered static mode available for
identication conrmation
PERFORMANCES
Isotope list:
according to ANSI N42-38, IEC, IAEA standards
Industrial, SNM, Medical and NORM radionuclides
Gamma detection and identification capability:
according to conguration, designed to exceed ANSI
N42-38 for pedestrian in dynamic mode
includes special processing for masked Isotopes such
as SNM masked by medicals or NORMs
Neutron detection capability:
according to conguration, designed to exceed ANSI
N42-38 / IAEA recommendation for pedestrian in
dynamic mode
COMMUNICATION
Ethernet (network) connectivity
DIMENSIONS
Body: 148 x 50,2 x 22,2 cm (57 x 19,73 x 8,74 in)
Base: Ø 32 cm (12.6 in)
Weight: 62 kg (137 lb)
Expert interface display
Portal interface display
Graphic «waterfall» display