RDS-80 Surface Contamination Meter
Portable Survey Meters
TECHNICAL SPECIFICATIONS:
Radiological Characteristics
radiation detected: alpha >2 MeV, beta
Emax
>100 keV, gamma and x-rays from 5 keV to 1.3 MeV
detector: end window GM tube, 1,5-2 mg/cm
2
MICA window active surface area 15,2 cm
2
measurement range: surface contamination 1 to 100 000 cps or 0.01 to 1 000 000 Bq/cm
2
alarm levels: freely adjustable alarm levels for contamination level
cps linearity: ±15% ±1 digit over the range. The Bq/cm
2
display is calculated from cps values using
isotope dependent coe cients
Functional Characteristics
display in either cps or Bq/cm
2
surface activity (Bq/cm
2
) display con gurable for di erent isotopes
cps follow-up by audible signal with frequency proportional to activity
visual and audible alarm: user settable for surface activity
histogram capability of up to 480 points with user settable logging interval
backlit display with six large digits
built-in self diagnostics
gamma background reduction for Bq/cm
2
measurements
Built-in infra-red port (IrDA)
Electrical Characteristics power supply: 2 alkaline batteries IEC LR6/AA size (recommended)
battery life time: at least 2000 hours at normal background with alkaline cells
(more than 1 year under normal operation)
battery alarm: two-step alarm for low battery voltage
electromagnetic compatibility: CE compliant
Mechanical Characteristics
rugged plastic case
GM tube Ø 4.4 cm (1.74”)
dimensions: 78 x 126 x 57 mm
weight: 280 g without batteries, 330 g with batteries
Environmental Characteristics
Temperature range:
-25...+55°C operational (-13... 131°F)
-40...+70°C storage (-40... 158°F)
Accessories
CSW software for parameter setting and histogram readings (can be downloaded free of charge at
www.mirion.com)
• CSW-Con guration SW full version with calibration key ( item no. 1233-246)
• wrist strap
• neck strap
Detector under protective grid
IrDA link