Manual

CAMERA OUTSTATION
Housing Material Stainless steel
Operating Temperature Ambient 0°Cto55°C(35°Fto131°F)
(Chalnicontube)
0°Cto40°C(32°Fto104°F)
(Vidicontube)
Operating Dose Rate 1kGy/hour(Chalnicontube)
30kGy/hour(Vidicontube)
Radiation Tolerance 1MGy [
60
Co](H
2
O);10
8
Rad [
60
Co]
(H
2
O)
Sealing IP68(IEC529)60mwaterdepth
(W.W.Fischerstainlesssteel
connectortypeSE105Z069-27)
IP66(IEC529)fullywashable
(LEMOstainlesssteelremote
handling cable connector type
FZJ3N318TLMY)
Maximum Operating Depth 20meters(66ft)
Maximum Submersion Depth 60meters(197ft)
Camera Midpoint Connector 24-way
Cable Connection 18-wayremotehandlingLEMO
or12-wayFischer
Pan and Tilt Speed: 6° per second
Travel:±180°(adjustable)
Size with Pan and Tilt 294mm(H)x267mm(W)xvarying
241to320(D)(11.6”x10.5”x
varying9.5”to12.6”)
Weight Approximately13kg(28.7lbs)
R981 NON-BROWNING LENS OPTIONS
Lens ViewingAngle:InAir
6:1 12mm-72mm zoom 40°W;7°N
6:1 24mm-144mm zoom 21W;3.5°N
3:1 8mm-24mm zoom 58°W;21°N
6mm, 9mm, 25mm fixed focal lens 73°;50°;20°respectively
W=Wide;N=Narrow
8 CHANNEL CAMERA SYSTEM SUB-RACK
Nominal Power Supply Input 100-120/200–240V
(auto-ranging);50/60Hz
Operation Range 85-132/170–264V
(auto-ranging);
47–440Hz
Power Requirement 150VAforafullypopulated
8-channel CCU
Outstation Cable Length 300m(656’)maximumCCUto
camera(consultIST)
Operating Ambient Temperatures Fullypopulated,convection
cooling:0°Cto40°C(32°Fto104°F)
Up to 6 channels,
convectioncooling:0°Cto50°C
(32°Fto122°F)Fullypopulated,
forcedaircoolingat500liters(132
gallons)/minute:0°Cto50°C(32°F
to122°F)
Relative Humidity 20%–75%non-condensing
Size 134mm(H)x483mm(W)x300mm
(D)
(5.3”x19”x11.8”)(excluding
handlesandconnectors)
Weight 7kg(15.4lbs)
CCU CONNECTOR TYPES
AC Power IEC320plug(ttedwithT4Afuse)
Camera Inputs (8 off) 15-wayDtypesocket
Video Outputs (8 off) 75RBNC
Genlock Input 75RBNC
(with75Rterminationswitch)
Sync Pulse Output 75RBNC
Serial Control Input 9-wayDtypeplug
Serial Control Loop Through 9-wayDtypesocket
CAMERA CHANNEL PERFORMANCE
(CAMERA AND CCU COMBINED)
Horizontal Resolution 550HTVlines
Sensitivity (faceplate) 1lux(Chalnicontube)
10lux(Vidicontube)
AGC Range -6db to 20db
Signal to Noise Ratio 43db(CCIRweighted,
AGCat0db)
Geometric Distortion 2% maximum
OPTIONAL ACCESSORIES
Camera Attachments Cameraallowsforupto4attach-
ment positions for a combination of
microphone and lights
In-Air or Underwater Lights Upto300Wusing50,75or100W
lamps
Lighting Sub-rack 8 Channel
Microphone Forin-airuseonly
Microphone Sub-rack 8 Channel
Integral version available.
R981 Specifications and Performance
R981 Camera Outstation Dimensions
80 (3.1")
dia
240 to 320 (9.5" to 12.6")
depending on lens type
140 to 150 (5.5" to 5.9")
depending on lens type
266 (10.5")
254 to 261
(10" to 10.3")
depending on
connector type
294 to 301
(11.6" to 11.85")
depending on
connector type