User guide

Since norms, speci cations and designs are subject to occasional change, please ask for con rmation of the information given in this publication.
Mirion Technologies (MGPI) SA
Route d’Eyguières
FR-13113 Lamanon
France
T +33 (0) 4 90 59 59 59
F +33 (0) 4 90 59 55 18
Mirion Technologies (MGPI) Inc
5000 Highlands Parkway
Suite 150
Smyrna, GA 30082
USA
T +1 770 432 2744
F +1 770 432 9179
Mirion Technologies (MGPI H&B) GmbH
Landsberger Strasse 328a
DE-80687 Munich
Germany
T +49 (0) 89515 13-0
F +49 (0) 89515 13 169
Mirion Commercial (Beijing) Co., Ltd.
Shanghai Jiangchang Commercial Branch
Room 801, 78 Jiangchang SanLu
Zhabei District, Shanghai 200436
PR of China
T +86 21 6180 6920
F +86 21 6180 6924
proTK™
Neutron Flux Instrumentation
www.mirion.com
145023EN-C
DAK 250 Digital Start-Up Channel
For the pulse range (DAK 250-i) with pulse detec-
tors and for the intermediate range (DAK 250-g) with
ionization chambers with linear or logarithmic output
signal and reactor period signal, optional module for
reactivity calculation
DGK 250 Digital Power Range Channel
For processing and numeric calibration of one or two
signal paths with boron coated ionization chambers
DSK 250 Local Power Range Channel
With four signal paths for in-core  ssion chambers in
the BWR
DWK 250 Digital Wide Range Channel
For combination of pulse and Campbell (RMS) signal
processing together with in-core (BWR) or ex-core
(PWR)  ssion chambers with pulse, intermediate, and
wide range  ux signal and reactor period signal
DLK 250 Power Distribution Channel
For monitoring the in-core  ux distribution in PWRs
with three or six signal paths for in-core SPN-detec-
tors
DMK 250 Average Power Range Channel
Together with the DSK 250 for the average  ux and
ow related  ux calculation in the BWR and for core
oscillation monitoring
The signal processing system TK 250 includes neutron  ux monitoring channels for BWR and PWR, and for research
reactors, which are designed and quali ed for applications within the reactor protection system:
Architecture of TK 250
signal processing channels
for neutron ux monitoring