User guide

Since norms, speci cations and designs are subject to occasional change, please ask for con rmation of the information given in this publication.
Mirion Technologies (MGPI) SA
Route d’Eyguières
FR-13113 Lamanon
France
T +33 (0) 4 90 59 59 59
F +33 (0) 4 90 59 55 18
Mirion Technologies (MGPI) Inc
5000 Highlands Parkway
Suite 150
Smyrna, GA 30082
USA
T +1 770 432 2744
F +1 770 432 9179
Mirion Technologies (MGPI H&B) GmbH
Landsberger Strasse 328a
DE-80687 Munich
Germany
T +49 (0) 89515 13-0
F +49 (0) 89515 13 169
Mirion Commercial (Beijing) Co., Ltd.
Shanghai Jiangchang Commercial Branch
Room 801, 78 Jiangchang SanLu
Zhabei District, Shanghai 200436
PR of China
T +86 21 6180 6920
F +86 21 6180 6924
PIS 205L
Samplers
PHYSICAL CHARACTERISTICS
Particulate:
Filter type: FSLW or equivalent Ø 47 to 57 mm
(1.8 to 2.2 in)
Iodine:
Cartridge type: silver zeolite or active charcoal
Ef ciency: > 99% for methyl iodine (HR 60%)
Filter/cartridge change frequency: one per week if
continuous trapping
ENVIRONMENTAL CHARACTERISTICS
Long term temperature:
+10°C to +40°C (+50°F to +104°F)
Periodic temperature:
+0°C to +45°C (+32°F to +113°F)
Storage temperature:
During 96 hours: -25°C to +85°C (-13°F to +185°F)
Pressure: 860 to 1060 hPa
MTBF: > 20 000 hours, with preventive maintenance
Protection index: IP32
PNEUMATIC CHARACTERISTICS
Nominal  ow rate:
By default: 35 l/min (1.25 scfm)
Minimum: 10 l/min (0.36 scfm)
Maximum: 50 l/min (1.79 scfm)
MECHANICAL CHARACTERISTICS
Dimensions: 895 mm x 435 mm x 370 mm
(35,3 in x 17.1 in x 14.5 in)
Weight: ~ 35 kg (~ 77 lb)
Color: gray RAL 7030 (decontaminable paint)
ELECTRICAL CHARACTERISTICS
Power supply: 230 Vac - 50 Hz
Data link outputs: 1 RS232 on DB9 connector on front
panel and 2 isolated RS485 via cable glands
Alarm relays: 3 DPDT relays
I/O: 1 isolated analog output and 1 isolated analog
input (0/4-20 mA)
SIGNALING
Alphanumeric display: measurement, status…
Sound alarm: buzzer 90 dBA at 1 meter
Visual alarm: 1 light (red)
REFERENCE STANDARDS
EMC: 2006/95/CE and 2004/108/CE, IEC61000-6-2
and IEC61000-6-4
ACCESSORIES
Maintenance and set-up software (MASS2)
Wall installation
FSLW  lter or equivalent
Zeolite cartridge or charcoal cartridge
Material to adapt to each sheath:
Flow rate control
Isokinetic sampling
www.mirion.com
145021EN-E