KG 50/51 SEC
Detectors
TECHNICAL CHARACTERISTICS
Interfacing of the KG 50 SEC with RAMSYS components
www.mirion.com
144875EN-B
Properties KG 50 SEC KG 51 SEC Acceptable Tolerance
Measuring range 1e–3 Gy/h … 1e+3 Gy/h
1e+3 Gy/h … 1e+5 Gy/h
1e–5 Gy/h … 1e+1 Gy/h
1e+1 Gy/h … 1e+3 Gy/h
± 20% of sensitivity
± 40% of sensitivity
Sensitivity for Cs-137
for Xe-133
Energy range
1.0e–9 A/(Gy/h)
1.2e–9 A/(Gy/h)
100 keV … 3 MeV
60 keV … 7 MeV
2.0e–8 A/(Gy/h)
2.4e–8 A/(Gy/h)
100 keV … 3 MeV
60 keV … 7 MeV
± 15% at 1 Gy/h
± 15% at 1 Gy/h
± 20% of sensitivity
± 50% of sensitivity
Detector housing
Gas lling
Electrodes
Radioactive embedded source
Stainless steel
Nitrogen/Argon, 1 bar
Aluminium
Am-241, 1 kBq
Stainless steel
Nitrogen/Argon, 20 bar
Aluminium
-
Operating voltage
Basic current from embedded source
800 V
1e-12 A approx.
800 V
-
Temperature range
Short term temperature range
Ambient pressure
Protection index
Dimensions (Ø × L, without cable)
Weight (without cable and connector)
Weight (with 60 m cables and connectors)
0 … 135°C (32 ... 275°F)
205°C (401°F) for 3h
0 … 7 bar
IK07 and IP67
50.8 mm × 440 mm
(1.9 in x 17.3 in)
2.1 kg (4.6 lb)
12.8 kg (28.2 lb)
0 … 135°C (32 ... 275°F)
205°C (401°F) for 3h
0 … 7 bar
IK07 and IP67
50.8 mm × 440 mm
(1.9 in x 17.3 in)
2.1 kg (4.6 lb)
12.8 kg (28.2 lb)
Cables
Cable length
Connectors
Metal shielded cable, ceramic insulation
0.3 to 70 m on request (1 to 229 ft)
Radiall HN, others on request