DSK/DMK 250
Neutron Flux Instrumentation
www.mirion.com
144969EN-C
DETECTORS AND INPUT SIGNALS
● Miniature in-core ssion chambers, e.g. WL 23630
(IST), MNK/MBK 61 (Siemens-Areva)
● Cable to the DSK 250: coaxial cable, no limitation of
length
● Detector supply: -50 ... -200 V individually
adjustable for each detector
● Range of detector current: 32 ... 4000 μA adjustable to
full scale
● Input signal for coolant ow: 0/4 ... 20mA
DIGITAL SIGNAL PROCESSING
● 80C31 multi-processor system
● Program memory: EPROM
● Parameter memory: CMOS-RAM with integrated
Li-battery
● Data interface: RS232 and/or RS485
● Internal LC-display: 2 x 16 characters
● DSK 250 processes four detector signals in four
individual signal paths:
○ Calibration of detector signal to power density
○ Alarm threshold for local density in relation to coolant
ow
● DMK 250 accumulates up to 64 detector lines (16
DSK 250):
○ Calculation and calibration of average reactor power
○ Calculation of ow related ux and margin to scram
○ Flux oscillation monitoring combining transient sup-
pression and fast response
OUTPUT SIGNALS
● DSK 250: ux density for each detector position
● DMK 250:
○ Average ux
○ Flow related ux
○ Magnitude of ux oscillations calibrated to reactor
power, e.g. 0 ... 125 %Pn
● Analog outputs: 0/4 ... 20mA/600 Ω, insulated
● Binary outputs: insulated relay change overs,
60V/0.5A or 125V/1A
OTHER CHARACTERISTICS
● DC power supply: 18 ... 33 VDC, approx. 1.6A at 24 V
(each DSK and DMK)
● Optional: AC power supply: 230 VAC or 115 VAC
+10%/-15%, approx. 40 VA
● Operating temperature: 0 ... 70°C (32 ... 158°F) for the
main electronics
● Mechanical vibrations: < 5 g, 5 ... 100 Hz
● 19” modular system according to IEC 60297
● Rack size (W×H×D): 483 mm × 133 mm × 280 mm
(19 in x 5.2 in x 11 in)
● Plug-in boards: 100 mm × 160 mm (3.9 in x 6.3 in)
DSK 250
front view