Manual

5000 Highlands Parkway
Suite 150
Smyrna Georgia 30082
USA
T +1.770.432.2744
F +1.770.432.9179
BP 1
F-13113 Lamanon
France
T +33 (0) 4 90 59 59 59
F +33 (0) 4 90 59 55 18
P.O. Box 506
FI-20101 Turku
Finland
T +358 2 4684 600
F +358 2 4684 601
Ruhrstrasse 49
D-22761 Hamburg
Germany
T +49 40 85193 0
F +49 40 85193 256
142422B
DRM-2(D)
Data Radiation Monitoring System
TECHNICAL SPECIFICATIONS:
Detector
•GMTubeZP-1301(orequiv)HighRange
•GMTubeZP-1201(orequiv)LowRange
•OptionalGMTubeZP-1300non-energycompensated
•OptionalCsI(2 x 2) detector
Measurement Range •5u/hrto1000R/hr (GM); 1 u/hr to 10 mr/hr (CsI)
•AutomaticswitchingbetweenGM detectorsat800mr/hrand600mr/hr
Accuracy + 10% of reading, within the measurement range
Energy Response + 20% at 70 keV to 1.1 MeV
Sensitivity (Cs137)
•17cps/mr/hr(LowRange):
•0.3cps/mr/hr(HighRange)
Display
•6SegmentLCD(non-backlit)-unitsmR/hoptionaluSv/h
Audible Alarms
Indicator Lamps
Alarm Acknowledgement Button
•TwosidemountedPiezosspeakers-alarmsoundlevel>95dB
•GreenandRedLEDstatusindicators
•OnePush-switch
Power
•Externalpowersupplyandbatterybackup:Externalpowersupply:Input120-250VAC,
•Output6-15Vdcwithlockingconnector
•BatteryBack-up:Three(3)1.2vNiMH2100mArechargeable
•Batteryoperatinglife:upto~8hourscontinuous
Temperature Range
•Operation:15
o
F to 122
o
F
•Storage:-5
o
F to 140
o
F
Humidity
•10%to95%RH(non-condensing)
Dimensions
•4.8”Wx8.4”Lx4.2”H(212mmx123mmx107mm)
Weight
•2.75lbs.(1247gm)
www.mirion-hp.com
DRM-2