TECHNICAL SPECIFICATIONS:
Detector
•GMTubeZP-1301(orequiv)HighRange
•GMTubeZP-1201(orequiv)LowRange
•OptionalGMTubeZP-1300non-energycompensated
•OptionalCsIdetector
Measurement Range
•0.05mr/hrto1000R/hr(0.5mSv/hrto10Sv/hr)
•Automaticswitchingbetweendetectorsat800mr/hr
and 600 mr/hr
Accuracy
•+10%ofreading,withinthemeasurementrange
Energy Response
•+20%at70keVto2MeV
Sensitivity(Cs137)
•17cps/mr/hr(LowRange):
•0.3cps/mr/hr(HighRange)
Power
•Externalpowersupplyandbatterybackup:
•Externalpowersupply:Input120-250VAC,Output
•9-15Vdcwithlockingconnector
•BatteryBack-up:Three(3)1.2vNiMH2100mA
rechargeable
•Batteryoperatinglife:upto12hourscontinuousoperation
Temperature Range
•Operation:15
o
F to 122
o
F
•Storage:-5
o
F to 140
o
F
Humidity
•10%to95%RH(non-condensing)
Dimensions
v4.25”Wx7”Lx2.5”H(108mmx178mmx64mm)
Weight
•2lbs.(907gm)