Operating instructions

PRELIMINARY GUIDE TO INSTALLATION AND OPERATION
UVP-101i | 3
Rear module switch settings:
The switch locations on the Symphonie-R-M rear module are shown in Figure 2.1.
- The reference switch LK1 is used to select the reference source for the imaging module. Selecting local
(LK1 position 2-3) drives the reference signal, connected to the rear module, to the imaging module.
- The reference signal selected by LK1 must be terminated by selecting ON (switch LK2 to position 2-3).
Fig. 2.1 Symphonie-R-M Rear Module Switch Location
Rear module physical installation:
In order to maintain the inter-rear module spacing, make sure to remove and replace one rear module at a
time. That is, at all times, there must be at least 15 rear modules installed.
To install a module, follow these steps.
1. Locate an empty compartment.
2. Carefully place the rear module between the rear module guides and slowly push the module towards
the front until it rests against the rear panel. It may require a light pressure to compress the EMI gaskets
on both sides.
3. Using a flat-edge screwdriver, secure the top and bottom screws to the frame.
Installing the UVP-101i
To install this module into a Symphonie frame follow these steps. For a closer look at module installation
and removal, refer to the Symphonie imaging housing frame Guide to Installation and Operation.
1. Remove the front panel door by pulling on the door handles and gently lowering it.
2. Select the compartment corresponding to the previously installed Symphonie-R-M rear module.
3. Carefully place the module between the module guides and slowly push the module towards the rear of
the frame until the module’s edge connector is secured to the rear module. A light pressure to mate the
connectors may be required. Pull lightly on the module, verifying that it does not move.
4. Replace the front panel door.