Setup guide

Table Of Contents
iControl Edge
Installation and Setup Guide
89
CARD (PHYSICAL PROBE) DENSITE ID ID of the associated Densité frame (e.g. DENSITE1).
EDGEVISION INPUT
(IR CONTROLLER /
PHYSICAL PROBE /
STREAMER)
EDGEVISION ID ID of the EdgeVision device associated with a particular EdgeVision Input
port.
EDGEVISION INPUT
(IR CONTROLLER /
PHYSICAL PROBE /
STREAMER)
INPUT Numerical port designation for a specific Input port of an EdgeVision device.
APPLICATION SERVER
ALLEGRO (STREAMER)
•PDU
•GC100
EDGEVISION
IP Unique IP address of the device.
Mandatory.
STBTUNER
(IR CONTROLLER)
•DVRTUNER
(IR CONTROLLER)
IR CONTROLLER
PORT
The infra-red controller port device ID.
This may be a GC100 port or an EdgeVision input.
PDU ID ID of the PDU (power distribution unit) powering this device
PDU OUTLET PDU outlet number being used by this device
APPLICATION SERVER HOSTNAME Host name of the Application Server.
Case sensitive.
Mandatory.
DENSITE NAME The name of a Densité frame.
CYCLER OCCURRENCES Number of alarm occurrences required before an alarm is triggered.
Default value:
1
POLLING
PERIOD
Total length, in milliseconds, of the period allowed for monitoring each
channel during a cycle, including the settling phase, and the listening
phase.
Default value is
45000 ms, i.e. 45 seconds.
DURATION Determines the amount of time, in milliseconds, required before an error
condition is considered as an alarm occurrence.
Default value is
30000 ms, i.e. 30 seconds.
3
SETTLING TIME Time allowed, in milliseconds, at the beginning of each polling period for
properly tuning a channel. Alarms are not actively monitored during this
period.
Default value is
5000 ms, i.e. 5 seconds.
GC100 PORT Active port number on a GC-1O0 network adapter.
Must be
4998.
VIRTUAL DEVICE
(VIRTUAL PROBE)
REAL DEVICE ID ID of the Densité probe associated with a specific virtual service.
Table 3-3: Devices worksheet contents (
Conti nued
)
Area Column Description