Setup guide
Table Of Contents
- Introduction to iControl Edge
- System Requirements
- Installation and Setup
- Key Concepts
- Task 1: Preparing to Install an iControl Edge System
- Task 2: Installing the iControl Application Server
- Task 3: Preparing a PC for Configuring the Application Server
- Task 4: Configuring the Application Server
- Task 5: Installing & Configuring EdgeVision Devices
- Task 6: Installing & Configuring Densité Systems
- Task 7: Installing & Configuring GC-100 Network Adapters
- Task 8: Installing Set-Top Boxes
- Task 9: Installing & Configuring Allégro Systems
- Task 10: Verification & Readiness Check
- Task 11: Managing the iControl Edge Configuration Files
- Task 12: Uploading and Applying iControl Edge Configuration Files
- Key Concepts
- Troubleshooting
- Installing PuTTY
- Using WinSCP
- Contact Us!

iControl Edge
Installation and Setup Guide
81
To capture IR signals from the remote control unit associated with a specific set-
top box model
1. Open a copy of the configuration file template in a text editor (e.g. Notepad).
2. Connect the GC-IRL IR Learner serial device to a serial port on your PC or laptop.
3. Launch the IR Learner Utility application (on the Start menu, point to All Programs, and
then click GC-IRL IR Learner Utility).
4. In the IR Learner Utility window, select the following options:
5. Click Connect to connect the device to the PC application.
6. Use the set-top box remote control unit to point to the GC-IRL device, and then press one
of the buttons on the remote (e.g. press 1).
The IR signal from the remote is converted to a string of characters placed on the clipboard.
7. Paste the content of the clipboard into the template file on the line whose header
corresponds to the button your pressed (e.g.
BUTTON_1).
The result will be something like the following:
BUTTON_1sendir,2:1,17,38000,1,1,341,171,21,63...
8. Repeat the same operation for every button on the remote control unit.
9. Save the text file, and name it after the set-top box model, with a
.conf extension.
10. Close the text editor.
11. When you are done with editing configuration files and spreadsheets, you will need to
upload them to the appropriate location on the server (see "Uploading and Applying
iControl Edge Configuration Files", on page 108).
Note: The IR Learner Utility and more information are available from the Support
Documents and Files section of Global Caché’s Web site.
See
http://www.globalcache.com/support/support_docs.html.
Option Value
End Timeout 100 ms
GC-100 Output Selected
Repeat count 1
Module 2
Connector 1
Note: The file name must not include spaces.