Setup guide

Table Of Contents
iControl Edge
Installation and Setup Guide
39
Restarting the System and Verifying the Configuration
Once you have specified all the settings your Application Server needs to be able to operate
on your local network, you must restart the system to apply the new configuration.
To restart the system and verify the configuration
1. On the Webmin home page, click Bootup and Shutdown.
Notes
•Clicking Save does not update the Application Server with the new
configuration. To apply your changes, you still need to click Apply
Configuration on the Network Configuration page or restart the system
through Webmin (see "Restarting the System and Verifying the
Configuration", on page 39).
The Application Server’s eth0 port is set to auto-negotiate, full duplex mode
by default. This setting should not be changed. The network switch to which
the Application Server is connected should also be set to auto-negotiate to
avoid data packet loss.
REQUIREMENTS
Make sure you meet the following conditions before beginning this procedure:
You are logged on to iControl Webmin (see "Logging on to Webmin", on page 30).
You have performed step 2 through step 4, inclusive, of "Configuring the Network", on
page 32.