Setup guide
Table Of Contents
- Introduction to iControl Edge
- System Requirements
- Installation and Setup
- Key Concepts
- Task 1: Preparing to Install an iControl Edge System
- Task 2: Installing the iControl Application Server
- Task 3: Preparing a PC for Configuring the Application Server
- Task 4: Configuring the Application Server
- Task 5: Installing & Configuring EdgeVision Devices
- Task 6: Installing & Configuring Densité Systems
- Task 7: Installing & Configuring GC-100 Network Adapters
- Task 8: Installing Set-Top Boxes
- Task 9: Installing & Configuring Allégro Systems
- Task 10: Verification & Readiness Check
- Task 11: Managing the iControl Edge Configuration Files
- Task 12: Uploading and Applying iControl Edge Configuration Files
- Key Concepts
- Troubleshooting
- Installing PuTTY
- Using WinSCP
- Contact Us!

iControl Edge
Installation and Setup Guide
37
8. Return to the Network Configuration page by clicking the Return arrow at the bottom of the
Routing and Gateways page.
Configuring the Ethernet Interface
The Application Server is shipped with the eth0 port turned on, in a default configuration that
permits an initial connection. The default IP address setting for the Application Server is
10.0.3.6, with subnet mask 255.255.0.0. This section describes how to reconfigure eth0 to
meet your local network requirements.
To configure the Ethernet interface
1. On the Network Configuration page, click Network Interfaces.
The Network Interfaces page appears. This page shows all Ethernet interfaces currently
active, and lists those that will be activated any time the system starts.
2. Click eth0 in the Name column.
The Edit Bootup Interface page appears.
Note: Clicking Save does not update the Application Server with the new
configuration. To apply your changes, you still need to click Apply Configuration on
the Network Configuration page or restart the system through Webmin
(see "Restarting the System and Verifying the Configuration", on page 39).
Note: Do not click Apply Configuration on the Network Configuration page.
Note: You must use eth0 as your main network interface. Client applications
(e.g. iC Navigator, iC Web, etc.) must be started via the Application Server’s eth0
IP address. The other Ethernet port (eth1) is also configurable, but is intended for
specialized use, such as connecting Miranda Densité frames and some third-party
devices. New Application Servers have the eth1 network interface disabled by
default.
REQUIREMENT
Before beginning this procedure, make sure you have navigated to the Network
Configuration page of Webmin (see page 29).