Setup guide
Table Of Contents
- Introduction to iControl Edge
- System Requirements
- Installation and Setup
- Key Concepts
- Task 1: Preparing to Install an iControl Edge System
- Task 2: Installing the iControl Application Server
- Task 3: Preparing a PC for Configuring the Application Server
- Task 4: Configuring the Application Server
- Task 5: Installing & Configuring EdgeVision Devices
- Task 6: Installing & Configuring Densité Systems
- Task 7: Installing & Configuring GC-100 Network Adapters
- Task 8: Installing Set-Top Boxes
- Task 9: Installing & Configuring Allégro Systems
- Task 10: Verification & Readiness Check
- Task 11: Managing the iControl Edge Configuration Files
- Task 12: Uploading and Applying iControl Edge Configuration Files
- Key Concepts
- Troubleshooting
- Installing PuTTY
- Using WinSCP
- Contact Us!

Installation and Setup
Alarms Worksheet
102
The Alarms worksheet defines which alarms will be monitored by your system.
Table 3-6, below, describes the worksheet contents:
Table 3-6: Alarms worksheet contents
Column Description
** Two asterisks (**), with no spaces, are positioned in the first column to indicate rows to be ignored,
such as rows containing column headers, or intended for future use.
1
DEVICE TYPE The device type to which this alarm applies:
•
DENSITE = Densité 3 Housing Frame
•
AS = Application Server
•
ACP1721 = ACP-1721 Digital Audio Control Probe
•
VCP1021 = VCP-1021 Composite Control Probe
•
DEC1002 = DEC-1002 10-Bit Composite to SDI Decoder
•
DEC1003 = DEC-1003 10-Bit Composite to SDI Decoder with Probing Option
•
DEC1023 = DEC-1023 12-Bit 3D Composite to SDI Decoder with Probing
•
UAP1781 = UAP-1781 8-Channel Universal Audio Processor
•
UAP1783 = UAP-1783 8-Channel Universal Audio Processor
•
AAP1741 = AAP-1741 4-Channel Analog Audio Processor
•
HCP1801 = HCP-1801 HD/SD Video Control Probe with Embedded Audio
ALARM GROUP The group to which this alarm belongs.
Will be displayed as a header in the alarm panel.
ALARM URI The alarm’s Uniform Resource Identifier.
ALARM NAME The name of the alarm that appears in the Detailed Signal Analysis views (see the Alarm Browser
section in the Web Monitoring chapter of the iControl Edge Operator’s Overview).