FRS-1801 | 33
3.4.16 The Alarm Config panel
This panel allows the alarm reporting of the FRS-
1801 to be configured. The panel opens in a new
window when the button is clicked, and can be
resized if needed.
The panel is organized in columns.
Status/Name
This contains an expandable tree listing all the
alarms reported by this FRS-1801 card.
• Each alarm name includes an icon that
shows its current status
• Some alarms may be text-only and the
alarm status is shown in the name and not
by a status icon
The Card LED, Overall alarm and GSM
contribution columns contain pulldown lists that
allow the level of contribution of each individual
alarm to the alarm named in the column heading
to be set.
• If there is no arrowhead in the box, there is
no pulldown and the alarm is not user-
configurable
• Card LED
This column allows configuration of the
contribution of selected individual alarms to the
status LED located on the front card edge. The
Card LED status is shown at the bottom of the
alarm tree in the Status/Name column.
• Overall Alarm
This column allows configuration of the
contribution of each individual alarm to the Overall Alarm associated with this card. The Overall Alarm is
shown in the upper left corner of the iControl panel, and also appears at the bottom of the Status/Name
column.
• GSM Contribution
This column allows configuration of the contribution of each individual alarm to the GSM Alarm Status
associated with this card. GSM is a dynamic register of all iControl system alarms, and is also an alarm
provider for external applications. The possible values for this contribution are related to the Overall alarm
contribution:
• If the Overall alarm contribution is selected as Disabled, the GSM alarm contribution can be set to any
available value
• If the Overall alarm contribution is selected as any level other than disabled, the GSM contribution is
forced to follow the Overall Alarm.
Fi
g
ure 3.3
8
Alarm Confi
g
uration
p
ane
l