Specifications
GUIDE TO INSTALLATION AND OPERATION
RCP-100 | 17
4.4.4 Requirement to Restart the RCP-100
There are a number of circumstances when it is important to RESTART the RCP-100, so that configuration
changes will be registered in the memory and implemented in operation. Some of these are listed in the
relevant sections of this manual, and are repeated here:
• When a card is moved to another position and its slot left empty (see page 10)
• When a change is made to the panel configuration (see page 12)
In addition, all RCP-100s which are clients of an iControl Application Server must be restarted if the following
changes are made in iControl Navigator:
• Device name change
• Group added/deleted
• Proc amps added/deleted
In all of these cases, RESTART the RCP-100 using the front panel RESET switch (see Fig. 2.1)
4.5 Disabled Cards
RCP-100 v2.40 and later is shipped from the factory with a number of Densité and Imaging cards disabled by
default. The RCP-100 will not be able to display or control those cards.
• These cards are either very simple cards – distribution amplifiers, for example – with nothing to
control, or complex cards which cannot usefully be controlled without a graphical interface, and are
therefore not provided with an RCP-100 menu.
The list of disabled cards is stored internally in a file named “client_disabled.xml”
• Full control of these cards can be restored by deleting the file from the RCP-100 internal memory.
• Customizing the list of disabled cards is possible by changing the content of this file
The file “client_disabled.xml” can also be stored on an external compact flash card that can be plugged into
the front panel CF port. At initialization, the RCP-100 will first try to find the file on an external CF card, and
will then look in its internal memory if none is found.
Please contact Miranda Technical Support for assistance on this issue.
Default List of Disabled Cards
Densité Cards Imaging Cards
SDA-1101 FIO-1811 HDA-1801 ACP-1721 SDA-101i SDM-111i
SDA-1102 FIO-1821 HDA-1802 DCP-1721 SDA 102i
SDA-1111 FIO-1831 HDA-1811 SCP-1121 SDA-111i VDA-101i
SDA-1112 FIO-1841 HDA-1812 VCP-1021 SDA-112i
SDA-1141 FIO-1851 HDA-1822 MSB-1121 SDA-801i VEA-101i
SDA-1161 HDA-1832 REF-1701 SDA-802i
VEA-1101 HDA-1841 SDA-103i VFC-123i
DDA-1111 VEA-1102 SDA-121i VFC-321i
DDA-1112
DDA-1131 VDA-1101
DDA-1132 VDA-1102