Hardware Description & Installation Manual M869-9902-114 17 December 2014
Notices Copyright & Trademark Notice Copyright © 2009–2014, Grass Valley USA, LLC. All rights reserved. Belden, Belden Sending All The Right Signals, and the Belden logo are trademarks or registered trademarks of Belden Inc. or its affiliated companies in the United States and other jurisdictions. Grass Valley, Miranda, Kaleido-X16, Kaleido-X, iControl, and Densité are trademarks or registered trademarks of Grass Valley USA, LLC. Belden Inc.
Kaleido-X16 Hardware Description & Installation Manual Important Safeguards and Notices This section provides important safety guidelines for operators and service personnel. Specific warnings and cautions appear throughout the manual where they apply. Please read and follow this important information, especially those instructions related to the risk of electric shock or injury to persons.
Notices The presence of this symbol in or on Grass Valley product means that it complies with all applicable European Union (CE) directives. The presence of this symbol in or on Grass Valley product means that it complies with safety of laser product applicable standards. Warnings • • • • • • • • • • • • • • • A warning indicates a possible hazard to personnel, which may cause injury or death.
Kaleido-X16 Hardware Description & Installation Manual • When installing this equipment, do not attach the power cord to building surfaces. • Products that have no on/off switch, and use an external power supply must be installed in proximity to a main power outlet that is easily accessible. • Use the correct voltage setting. If this product lacks auto-ranging power supplies, before applying power ensure that each power supply is set to match the power source. • Provide proper ventilation.
Notices Mesures de sécurité et avis importants La présente section fournit des consignes de sécurité importantes pour les opérateurs et le personnel de service. Des avertissements ou mises en garde spécifiques figurent dans le manuel, dans les sections où ils s’appliquent. Prenez le temps de bien lire les consignes et assurez-vous de les respecter, en particulier celles qui sont destinées à prévenir les décharges électriques ou les blessures.
Kaleido-X16 Hardware Description & Installation Manual La marque ETL Listed d’Intertek pour le marché Nord-Américain certifie que l’appareil visé a été testé par Intertek et reconnu conforme aux exigences applicables en matière de sécurité électrique en vigueur au Canada et aux ÉtatsUnis.
Notices • Après tout travail d’entretien ou de réparation, faites effectuer des contrôles de sécurité par le personnel technique qualifié. Mises en garde • • • • • • • • • Les mises en garde signalent des conditions ou des pratiques susceptibles d’endommager l’équipement. Veuillez vous familiariser avec les mises en garde cidessous : L’appareil est conçu pour être installé dans un endroit à accès restreint.
Kaleido-X16 Hardware Description & Installation Manual • Pour plus de sécurité, vérifiez périodiquement la valeur de résistance du bracelet antistatique. Elle doit se situer entre 1 et 10 mégohms. • Si vous devez mettre une carte de côté, assurez-vous de la ranger dans un sac protecteur antistatique. • Les cartes qui sont reliées à un châssis ou boîtier métallique mis à la terre ne nécessitent pas de protection antistatique spéciale. Remplacement et élimination des piles L’appareil renferme une pile.
Notices This equipment has been tested and found to comply with the requirements of the EMC directive 2004/108/EC: • EN 55022 Class A Radiated and conducted emissions • EN 61000-3-2 Limits for harmonic current emissions • EN 61000-3-3 Limitation of voltage fluctuations and flicker • EN 61000-4-2 Electrostatic discharge immunity • EN 61000-4-3 Radiated, radio-frequency, electromagnetic field immunity • EN 61000-4-4 Electrical fast transient immunity • EN 61000-4-5 Surge transient immunity • EN 61000-4-6 Con
Table of Contents 1 Kaleido-X16 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Mechanical Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Frame and Electrical Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Kaleido-X16 Installation The Kaleido-X16 is a 1RU, multi-image display processor with high image quality and a rich feature set. This chapter contains physical descriptions, installation instructions and connection information for the Kaleido-X16 frame. Summary Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Mechanical Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Kaleido-X16 Installation Port Availability Kaleido-X16 as a router The Kaleido-X16 can behave as a router, with 16 input channels as sources and the two RT OUT outputs as destinations Superior display Highest quality multi-image output without compression, with superior on-screen graphics, for the most critical live monitoring applications 128 audio channels Unprecedented audio performance with the ability to monitor up to 128 channels of audio, including embedded, discrete analog, discrete AES from A
Kaleido-X16 Hardware Description & Installation Manual The Kaleido-X16 system is available in two model types: a single-head model (Kaleido-X16-S) and a dual-head model (Kaleido-X16-D). Throughout this manual, Kaleido-X16 refers to both models unless it is necessary to distinguish the single-head model from the dual-head model. Kaleido-X16-D There are two heads (Head 1 and Head 2) on the dual-head Kaleido-X16 (Kaleido-X16-D). The Input and Output connections are as follows.
Kaleido-X16 Installation Mechanical Installation Mechanical Installation Unpacking Make sure the following items have been shipped with your Kaleido-X16. If any of these are missing, contact your distributor or Grass Valley.
Kaleido-X16 Hardware Description & Installation Manual 2 Insert the Kaleido-X16 frame at the designated location within the rack, and secure the front of the frame to the rack by using suitable screws and washers (not included). IMPORTANT Mobile Installation If you are deploying your Kaleido-X16 in a mobile unit, it is your responsibility to make sure the back of the multiviewer is securely attached to the rack.
Kaleido-X16 Installation Frame Reference Input CPU Video Inputs CF Activity DVI Inputs SDTI General Status Severity LTC LEDs on the front of the frame (behind the cover) The LEDs on the front of the frame (behind the cover) indicate the following conditions depending on their color and whether they are blinking or not: LED Status LED Green Blinking green Red Blinking red Yellow Blinking yellow CPU Normal operation Application booting Error Live Update OS Booting N/A Front cover is clo
Kaleido-X16 Hardware Description & Installation Manual Monitoring the Temperature of the Kaleido-X16 For optimal performance, it is strongly recommended that you operate the Kaleido-X16 multiviewer in an environment with an ambient temperature between 0 °C and 40 °C. IMPORTANT When measuring the ambient room temperature, take your readings from directly in front of the Kaleido-X16 frame.
Kaleido-X16 Installation Power Supplies PSU A removed from Slot A Slot A Slot B PSU slot locations Two PSUs installed in a frame; front cover removed Removing a Power Supply To remove a power supply 1 Open the front cover of the frame and locate the power supply (PSU) you would like to remove (either the left or the right side). 2 Pull on the handle on the right side of the PSU and pull the PSU out of the frame.
Kaleido-X16 Hardware Description & Installation Manual Power socket for PSU B Power socket for PSU A IMPORTANT • A Kaleido-X16 multiviewer can draw 4.0 amps of current. Ensure that the circuit to which the frame is connected can handle that load, and that of any other connected devices. • If you only have one PSU, make sure you plug your power cable into the power connector on the right side of the rear connector panel (as you face the rear of the frame).
Kaleido-X16 Installation Ventilation Air flow through the Kaleido-X16 frame Frame Cooling Fans Air intake for the multiviewer is handled by six fans located near the front of the frame and two heat sinks near the rear of the frame. The fans draw air into the frame through a grille and filter in the front cover. The heat sinks help to exhaust air out through grates on either side (see diagram, above). IMPORTANT The Kaleido-X16 multiviewer requires a constant flow of cooling air during operation.
Kaleido-X16 Hardware Description & Installation Manual CompactFlash In order to boot the CPU, you must ensure the appropriate CompactFlash (CF) card is properly inserted in the CF slot (accessible from the front of the Kaleido-X16 frame). The CF card contains the operating system required for a system boot. CF slot on front of Kaleido-X16 frame For more information about starting the Kaleido-X16, see the Setting up the Kaleido-X16 chapter in the Kaleido-X16 Quick Start Guide.
Kaleido-X16 Installation Inputs Connector label Connector type Function AUDIO I/O HD-26 (female) Supports two AES3 audio outputs or two analog audio outputs for monitoring. SDTI BNC Multiplexed audio from an external audio box (Audio Bridge Terminal). ETHERNET RJ-45 100 Base-T Ethernet connection. USB USB Connect a mouse, keyboard, or USB flash memory for software upgrade or data backup.
Kaleido-X16 Hardware Description & Installation Manual Mosaic Outputs HDMI Outputs There is one HDMI output for each output head (MV OUT 1, MV OUT 2). See HDMI Outputs on page 25 for specification details. The HDMI connection is a high definition connection for the multiviewer output, which carries audio and video, and can support resolutions up to 1920 × 1200.
Kaleido-X16 Installation Router Outputs Router Outputs The Kaleido-X16 can be configured as a router. In this configuration, up to two Kaleido-X16 channels are considered as sources, and the destinations are the two RT OUT ports on the rear connector panel: BNC connectors for router outputs For more information about Router Output specifications, see Router Outputs, on page 27. For more information about Routers and the Kaleido-X16, see the Routers chapter of the Kaleido-X User’s Manual.
Kaleido-X16 Hardware Description & Installation Manual Audio I/O TBA Pinout on the Kaleido-X16-D The Audio I/O TBA pinout on the Kaleido-X16-D is as follows: Bottom row Center row Top row 19 GND 10 AES Out 1 (+) 1 AES Out 1 (-) 20 GND 11 AES Out 2 (+) 2 AES Out 2 (-) 21 GND 12 GND 3 GND 22 GND 13 Analog Left Out 1 (+) 4 Analog Left Out 1 (-) 23 GND 14 Analog Right Out 1 (+) 5 Analog Right Out 1 (-) 24 GND 15 Analog Left Out 2 (+) 6 Analog Left Out 2 (-) 25 GND 16 Analog Right Ou
Kaleido-X16 Installation Control Control The connectors located in the middle of the rear connector panel (the yellow and orange color-coded area) are Control connectors. BNC connectors for LTC inputs RJ-45 connectors (2) for RS-422 serial connections RJ-45 Ethernet connector DB-44 connector for GPI I/O USB connectors (2) Linear Time Code (LTC) The Kaleido-X16 supports two linear time code (LTC) inputs over BNC connectors.
Kaleido-X16 Hardware Description & Installation Manual Bottom row Middle row Top row Pin # Description Pin # Description Pin # Description 35 GND 20 GPI Input 24 5 GPI Input 25 36 GPI Input 26 21 GPI Input 27 6 GPI Input 28 37 GPI Input 29 22 GPI Input 30 7 GPI Input 31 38 GPI Input 20 23 GPI Input 32 8 GPI Input 18 39 GPI Input 16 24 GPI Input 19 9 GPI Input 15 40 GPI Input 14 25 GPI Input 17 10 GPI Input 12 41 GND 26 GPI Input 13 11 GPI Input 10 42 GPI
Kaleido-X16 Installation Control To facilitate cabling of the GPI inputs and outputs, a terminal block adapter is available separately (order code KXA-TBA-44). The GPI Terminal Block Adapter accommodates up to 44 terminal block connections using positive and negative terminal connections. Each column on the terminal block has 6 positive and 6 negative terminal connections that correspond to each pin position. Negative pins (labelled with an N) on the Terminal Block Adapter are not used as connections.
Kaleido-X16 Hardware Description & Installation Manual Kaleido-X16 GPI Terminal Block Adapter pinout For more information about: • GPI specifications, see GPI INPUT (up to 32) and GPI OUTPUT (up to 4), on page 29. • triggering GPI output events, see “Triggering GPI Output Events” in the Operation of the Monitor Wall chapter of the Kaleido-X User’s Manual. • calibrating GPI lines, see “Calibrating GPI Lines” in the Calibrating the Kaleido-X chapter of the Kaleido-X User’s Manual.
Kaleido-X16 Installation Control USB (1) connector on front of Kaleido-X16 One USB connector on the front of the frame RS-422 The Kaleido-X16 supports two RS-422 serial inputs over RJ-45 connectors. These inputs allow the Kaleido-X16 to connect to external serial devices such as a router, production switcher, or router controller. Note: The Kaleido-X16’s two RS-422 ports each have an RJ-45 connector in order to preserve space on a busy panel.
Kaleido-X16 Hardware Description & Installation Manual Pinout of each RS-422 port’s RJ-45 connector on the multiviewer RJ-45 DE-9 male DE-9 female Pinout of crossover adapter (Grass Pinout of RS-422 Valley part no. 1792-3700-100) connector on SMPTE master device Standard wiring between multiviewer and devices wired to SMPTE “master” specification (e.g. Philips Jupiter router control system, Miranda Presmaster PCS) Note: The two RS-422 ports on the Kaleido-X16 side have no ground pin.
Kaleido-X16 Installation Replacing a Defective Power Supply Replacing a Defective Power Supply In the event of a power supply failure, the unit will switch to the redundant power supply for its power source. If a PSU’s LED is not green, you must replace the unit. For more information about removing and reinstalling a power supply, see Power Supplies, on page 7.
Specifications This chapter lists equipment specifications for the Kaleido-X16 multiviewer. Inputs Video Signal Inputs The Kaleido-X16 frame supports 16 signal inputs. The supported input types include Composite, SD/SDI, HD-SDI, and 3Gbps (auto-detected). The processing delay is two fields if the video inputs are genlocked, and two or three fields if the video inputs are not genlocked. Signal inputs require BNC connectors.
Specifications DVI Graphic Inputs HD-SDI Inputs (continued) Formats 720p24, 720p25, 720p29.97, 720p50, 720p59.94 1080i50, 1080i59.94 1080PsF23.98, 1080PsF24, 1080PsF25, 1080PsF29.97 1080p23.98, 1080p24, 1080p25, 1080p29.97 Note: The Kaleido-X software does not distinguish between 1080PsF25 and 1080i50, and neither between 1080PsF29.97 and 1080i59.94. Both 1080PsF25 and 1080i50 are reported as 1080i50, and both 1080PsF29.97 and 1080i59.94 are reported as 1080i59.
Kaleido-X16 Hardware Description & Installation Manual H frequency 37 kHz to 96 kHz Refresh rate 50/59.94 Hz Cable length 3.6 m (12 ft) with Altinex CB4012DV Connector DVI-I (dual link) Outputs Mosaic Outputs The Kaleido-X16 frame supports two HDMI outputs. HDMI Outputs Signal DVI-D Resolution From 1024 × 768 to 1920 × 1200 NI H frequency 37 kHz to 96 kHz Refresh rate 50/59.94 Hz Cable length 5 m (15 ft)1 Connector HDMI Supported cable types HDMI to HDMI, or HDMI to DVI-D 1.
Specifications Mosaic Outputs Note: Users can customize their own timing rates through the XEdit software for resolutions ranging from 1024 × 768 up to 1920 × 1200 pixels. The Kaleido-X16 frame supports two 3G/HD-SDI monitoring outputs (with embedded audio). HD-SDI Monitoring Outputs Signal 4:2:2 SMPTE ST 292-C (1.5 Gbps) Formats 720p59.94 1080i50 1080i59.94 1080PsF23.98 1080PsF24 1080PsF25 1080p23.98ß 1080p24 1080p29.
Kaleido-X16 Hardware Description & Installation Manual Router Outputs The Kaleido-X16 frame supports two 3G/HD/SD-SDI router outputs. SD-SDI Router Outputs Signal 4:2:2 SMPTE ST 259-C (270 Mbps), SMPTE ST 272:1994 Formats 525 and 625 Cable length 225 m (738 ft) (Belden 1694A) Return loss >15 dB up to 270 MHz Additive jitter < 0.2 UI p-p (wideband) Connector type BNC HD-SDI Router Outputs Signal 4:2:2 SMPTE ST 292-C (1.5 Gbps) Formats 720p59.94 1080i50 1080i59.94 1080PsF23.
Specifications Audio I/O Audio I/O The Kaleido-X16 frame supports one SDTI audio input. SDTI Audio Input Signal SMPTE ST 305 (up to 128 channels/64 AES) Cable length 250 m (820 ft) (Belden 1694A) Connector BNC The Kaleido-X16 supports audio monitoring through its HD-26 connector. The supported formats are the AES3 digital audio, and analog audio.
Kaleido-X16 Hardware Description & Installation Manual The Kaleido-X16 supports 32 GPI inputs and 4 GPI outputs, on a DB-44 female connector. GPI INPUT (up to 32) Description Contact closure to GND Pull-up voltage 3.3 Volts Source current 30 μA when input shorted Low-level activation 0.
Specifications Frame Max current 4A Max power 300 W Dimensions H: 45 mm (1.75 in) (1 RU) W: 451 mm (18 in) + mounting flange for standard 19-inch rack D (with cover and connectors): 641 mm (25.25 in) D (without cover and connectors): 591 mm (23.25 in) 30 Full spec. temp. range 0-40 °C (ambient) Storage humidity 90% RH non-condensing Functional humidity 65% RH non-condensing Weight (2 PSUs) 10.5 kg (23 lbs) Weight (1 PSU) 9.
Disposal and Recycling Information Your Grass Valley equipment comes with at least one lithium button battery (Li-MnO2) located on the main printed circuit board. The batteries are used for backup and should not need to be replaced during the lifetime of the equipment. Before disposing of your Grass Valley equipment, please remove the battery as follows: 1 Make sure the AC adapter is unplugged from the power outlet. 2 Remove the protective cover from your equipment.
Disposal and Recycling Information WARNING (continued) Risk of exposure occurs only if the battery is mechanically or electrically abused. The most likely risk is acute exposure when a cell vents. In the event of a battery leak, do not allow battery liquid to come in contact with skin or eyes. Seek medical help immediately in case of ingestion, inhalation, skin or eye contact, or suspected exposure to the contents of an opened battery. For more information about recycling, please contact Grass Valley.
Contact Us Grass Valley Technical Support For technical assistance, contact our international support center, at 1-800-547-8949 (US and Canada) or +1 514 333 1772. To obtain a local phone number for the support center nearest you, please consult the Product Support section of Grass Valley’s Web site, at http://www.grassvalley.com/ support/contact. An online form for e-mail contact is also available from the Web site. Corporate Head Office Grass Valley 3499 Douglas-B.