SDI Output Reclocking On/Off selection
5. Click File|Save or the Save tab in the XEdit application toolbar.
Configuring Alarm Threshold
To configure alarm threshold:
1. Repeat steps 1 to 3 from “Configuring Calibration instruction set.
2. Set the threshold value from left to right for that specific alarm until you have reached the desired
setting.
Overload (left/right): Select the level (in either dB, dBFS) above which audio will be considered
overloaded.
Silence (left/right): Select the level (in dB, dBFS) below which audio will be considered silenced.
Out of Phase: Select the level below which audio will be considered out of phase. The sensitivity is
between -1 and +1, where -1 means completely out of phase and +1 means perfectly in-phase.
Mono: Select the level above which audio will be considered mono. The sensitivity is between -1 and
+1, where -1 means completely out of phase and +1 means perfectly in-phase.
Black Detection Threshold: set the level (in IRE or mV) below which the signal will be considered to be
black.
Luma Too High Detection Threshold: Define the level above which Luma Too High will be reported. Can
be specified in IRE or mV.
Freeze Sensitivity: Freeze detection is done by comparing successive frames. Noise in the signal could
disrupt this process, so filtering is added to remove it. Adjust the sensitivity to suit the signal being
monitored (0 = Noisy, 100 = Clean).