Installation manual

Installation Manual
2
7
3
8
1
For pins 2/7 and 3/8, using Belden 8162 or similar is recommended, 24AWG.
2 Twisted Pairs individually shielded, both GND and the Overall foil connected to pin 1
Notes:
Pair 1
Pair 2
Foil
GND shield
GND shield
(overall shield)
Pair 3
Pair 4
Foil
GND shield
GND shield
(overall shield)
DE9-M DE9-M DE9-M
RS-422 Multi-drop Cable Example
DE9-M
2: For PINS 4 and 5, wires should be 20AWG.
120Ω 120Ω
3:
As illustrated, it is strongly recommended to get 12V required for the RCP from
an external DC supply or AC/DC adaptor. It shall deliver 3W or more (250mA
or more). The distance between the supply and the RCP should be the
shortest possible.
External DC
power supply
or AC/DC
adaptor
+12V
GND
1:
2
7
3
8
1
4
5
2
7
3
8
1
Kaleido-RCP
Device #1:
Kaleido-Classic,
Kaleido-K2,
Kaleido-Alto
or Kaleido-Quad
Device #2:
Kaleido-Classic,
Kaleido-K2,
Kaleido-Alto
or Kaleido-Quad
Device #n:
Kaleido-Classic,
Kaleido-K2,
Kaleido-Alto
or Kaleido-Quad
GND shield
GND shield
(overall shield)
Pair 5
Pair 6
Foil
Tx-
Tx+
Rx-
Rx+
DE9-M
Device #3:
Tango
Pair 7
Pair 8
Foil
GND shield
GND shield
(overall shield)
DE9-M
2
7
3
8
1
Device #4:
Kaleido-Classic,
Kaleido-K2,
Kaleido-Alto
or Kaleido-Quad
8
3
7
2
1
2
7
3
8
1
4:
As illustrated, the Tango has Tx and Rx
signals located at different pins than other
Kaleido products.
Figure 2.5.2 Kaleido Alto/Kaleido-RCP interconnection for cascading multiple frames