Operating instructions
GUIDE TO INSTALLATION AND OPERATION 
32 | IRD-3802 
3.4.12 The Alarm Config panel 
This panel allows the alarm reporting of 
the IRD-3802 to be configured. The panel 
opens in a new window when the button 
is clicked, and can be resized if needed. 
The panel is organized in columns. 
Status/Name 
This contains an expandable tree listing 
all the alarms reported by this IRD-3802 
card. 
• Each alarm name includes an icon 
that shows its current status 
• Some alarms may be text-only and 
the alarm status is shown in the 
name and not by a status icon, 
e.g. 
The Card LED, Overall alarm and GSM contribution columns contain pulldown lists that allow the level of 
contribution of each individual alarm to the alarm named in the column heading to be set. 
  If there is no arrowhead in the box, there is no pulldown and the alarm is not user-configurable 
Levels associated with these alarms: 
The pulldown lists may contain some or all of the following options: 
The alarm makes no contribution (black icon)
The alarm is of minor importance (yellow icon)
The alarm is of major importance (orange icon)
The alarm is of critical importance (red icon)
The alarm exists but has no effect (used for text and composite alarms)
Shortcut: if you click in one of the columns beside a major heading in the Status/Name column (where 
there is no pulldown shown), you will open an “invisible” pulldown that lets you assign a level to all alarms 
in that section of the column simultaneously. 
•  Card LED 
This column allows configuration of the contribution of each individual alarm to the state of the Status LED 
located on the front panel this card. 
•  Overall Alarm 
This column allows configuration of the contribution of each individual alarm to the Overall Alarm 
associated with this card. The Overall Alarm is shown in the upper left corner of the iControl panel, and 
also appears at the bottom of the Status/Name column. 
Figure 3.29  Alarm Configuration Panel 