Operating instructions
GUIDE TO INSTALLATION AND OPERATION 
IRD-3802 | 11 
3 Operation 
3.1 Control options 
The IRD-3802 can be controlled in two different ways: 
•  The local control panel and its push-buttons can be used to move through a menu of parameters and to 
adjust parameter values (see section 3.3). 
•  Miranda’s iControl system can be used to access the card’s operating parameters from a remote 
computer, using a convenient graphical user interface (GUI). (see section 3.4) 
3.2  Card-Edge Status LED 
The status monitor LED is located on the front card-edge of the IRD-3802, and is visible through the front 
access door of the DENSITÉ frame. The chart shows how the various error conditions that can be flagged on 
the IRD-3802 affect the LED status. 
•  If a cell in the chart is gray, the error condition cannot cause the LED to assume that status 
•  If more than one LED status is possible for a particular error condition, the status is configurable. 
  See Section 3.4.12 for details. 
•  The factory default status is shown by a , and forced status by an X 
The LED will always show the most severe detected error status that it is configured to display, and in the 
chart error severity increases from left to right, with green representing no error/disabled, and flashing red the 
most severe error. 
Led Color 
Alarm Name/Error Report 
Green  Yellow Red 
Flashing 
Red 
Description 
Card booting   
X 
After power-up, the led becomes yellow until 
Linux is properly booted (takes about 40s) 
Hardware/System Failure       
X 
Major hardware or system failure. In some 
cases, the error log will show the reason 
No Rear Detect   
X 
As per densité 
No TS Input Signal     
 
  No MPEG TS input detected 
TS Limit   
   
TS has more than 128 PIDs or more than 64 
programs or more than 1024 tables 
No Video Signal     
 
The MPEG TS input might be present, but 
no video signal is available for decode 
No Audio Signal   
   
The video may be present, but no audio 
stream is valid for decode 
No Reference Signal 
  
  No reference signal is detected 
Reference Mismatch   
   
  A reference mismatch is detected 
Program not synchronized 
     
  The decoded video is not synced on PCRs 
Test Bars ON 
X 
The card is in test mode with color bar 
activated 
If the LED is Flashing Yellow, it means that the card is selected for local control using the Densité frame’s 
control panel. See Section 3.3 for details. 